C. When routing the cable on-wall:
(1) Cut off the cable guide of the front case with using a knife or a
nipper.
(2) Deburr the edge of the cable guide.
(3) Fix the rear case by securing it with attached screws (2 places).
Remote controller cable
Rear case
5.3.5 Connect the cable to the terminals
Tightening torque
Terminal screw
1. 12V (Red)
2. Signal (White)
3. COM (Black)
To avoid an excessive tension or pressure to the terminal block,
fix the remote controller cable with the cable tie (small) properly.
Turn off a cable tie (small) by all means on tube.
Cable tie (small)
Tube
2 mm
GOOD
screws.
5
Cut off
Front case
Epoxy putty
Screws
Hole for cable tie
PROHIBITED
CAUTION

5.3.6 Setting the DIP switch

CAUTION
manual or the operating manual supplied with the air conditioner. Please
set DIP switch according to designation.
Use an insulated screwdriver to set the DIP switches.
Set DIP switch No. 1 to ON to enable the memory backup of the settings
information.
Memory backup setting
if there is a power failure.
even if the DIP switch is turned off.
Switch state
No.
OFF
ON
1
Validity
Invalidity
DIP
switch
2
5.3.7 Attach the front case
Front case
GOOD
CAUTION
case to fall off.
DIP switch
1 2
Front case (back side)
Detail
Memory backup setting
* Set to ON to use batteries for
the memory backup.
settings information stored in
memory will be deleted if there
is a power failure.
Dual remote controller setting
* Refer to "6.1.2. Dual remote
controllers".
( Factory setting)
Click!
PROHIBITED