Download Print this page

Features; Installation - Smeg PUM60X Instruction Manual

Advertisement

Trouble Shooting
If any problem occurs, please detach the plug from the sock-
et and contact the manufacturer or its service agent or a sim-
ilarly qualified person in order to avoid a hazard.
Problem
Cause
Light on, but motor
The outlet valve is blocked
does not work
The capacitor has failed
The control switch has Call for technical service
Light does not work,
No power supply
motor does not work
Fuse has blown
Vibration
The propeller is damaged or
unbalanced
The hood is not installed
correctly
Insufficient
suction
The distance between the
effect
hood and the cooker is too
The filters are saturated
Solution
Detach flue and duct then
turn on the hood to check if
the valve opens
Call for technical service
Plug another appliance into
the socket to confirm there is
power supply
Open up the plug and replace
the 13A fuse
Call for technical service
Review the installation in-
structions & check the instal-
lation again for loose screws,
brackets or connections
Check that the distance is
between 650mm to 700mm
Clean the filters from grease
residue and replace after

Features

2.1 This appliance is manufactured from top quality materials,
and offers superb streamlined effects.
2.2 With high suction power and low noise, it is designed to
remove cooking fumes from your kitchen quietly & effectively.
Installation(duct is not supplied)
3.1 The range hood should be mounted at a distance of 650-
750mm from the cooking surface for safety & optimum perfor-
mance (If the instructions for installation of the gas hob specify
a greater distance, this has to be taken into account.) (see pic1).
That exhaust air must not be discharged into a flue which is
used for exhausting fumes from other appliances burning gas or
other fuels.
3.2 To install, drill 2 holes of Ø8mm on a
sturdy wall and in line with the hood.
3.3 Insert expending screws into the holes.
3.4 Fix drilling template on the wall (see pic
2).
3.5 The appliance should be embedded into
the wall unit or another support. This process
should be carried out by 4 screws suitable
for the kind of unit following the instructions
for the drilling of the holes as shown in (see
pic 3).
3.6 Attach the duct to the one way valve, and connect it to the
kitchen outlet vent (see pic 4).
pic 1

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Pum90x