Code
Contents
0930
EEPROM bus error
1010
Lift motor error
When the lift motor is driven,
the motor over-current detec-
tion signal is detected continu-
ously for 50 times (5 s) at 100
ms intervals.
After the lift motor is driven,
the ON status of lift sensor
cannot be detected for 8 s.
The cassette installed confir-
mation message is displayed
on the operation panel, and
even if the cassette is opened
and closed, the cassette
installed confirmation mes-
sage is displayed 5 times suc-
cessively.
1020
PF lift motor error
(paper feeder 1)
When the lift motor is driven,
the motor over-current detec-
tion signal is detected continu-
ously for 50 times (5 s) at 100
ms intervals.
After the lift motor is driven,
the ON status of lift sensor
cannot be detected for 8 s.
The cassette installed confir-
mation message is displayed
on the operation panel, and
even if the cassette is opened
and closed, the cassette
installed confirmation mes-
sage is displayed 5 times suc-
cessively.
Causes
Defective drum
Replace the drum unit (see page 1-5-21).
PWB (EEPROM).
Defective engine
Replace the engine PWB and check for cor-
PWB (EEPROM).
rect operation (see page 1-5-27).
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-27).
Defective main
Replace the main PWB and check for cor-
PWB.
rect operation (see page 1-5-30).
Defective bottom
Check to see if the bottom plate can move
plate elevation
smoothly and repair it if any problem is
mechanism in the
found.
cassette.
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Lift motor and engine PWB (YC27)
Defective drive
Check if the gears rotate smoothly. If not,
transmission sys-
grease the bushes and gears. Check for
tem of the lift
broken gears and replace if any.
motor.
Defective lift motor. Replace the lift motor
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-27).
Defective bottom
Check to see if the bottom plate can move
plate elevation
smoothly and repair it if any problem is
mechanism in the
found.
cassette.
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
PF lift motor and PF main PWB (YC7)
Defective drive
Check if the gears rotate smoothly. If not,
transmission sys-
grease the bushes and gears. Check for
tem of the PF lift
broken gears and replace if any.
motor.
Defective PF lift
Replace the PF lift motor
motor.
Defective PF main
Replace the PF main PWB (Refer to the ser-
PWB.
vice manual for the paper feeder).
1-4-8
Check procedures/
corrective measures
2PA