REMOTE Specifications

SERIAL terminal

External operations can be performed via the RS-232C interface.
The following diagram and the table on the following SERIAL terminal pin arrangement and connections.
For details on systems using SERIAL, be sure to consult your dealer.
1
N.C.
2
TXD
3
RXD
4
DSR
5
GND
6
DTR
7
CTS
8
RTS
9
N.C.
Signal level
Synchro system
Transfer rate
Parity
Data length
Stop bit
Flow control
64
External Device Side
1
2
3
4
5
6
7
8
9
Description
Not connected
Transmission data
Reception data
Connected inside
Ground
Connected inside
Connected inside
Connected inside
Not connected
RS-232C compliant
Asynchronous
9600 bps
None
8 bit
1 bit
None
(Straight)
N.C.
RXD
TXD
DTR
GND
DSR
RTS
CTS
N.C.
Command format
STX (02h)
Command
The command is the 3-character string starting
with STX and ending with ETX.
Append any data after the colon (:) following the
command, as required.
Response formats
1.
STX (02h)
2.
STX (02h)
3.
Error response
STX (02h)
Error codes
Error codes
ER001: Invalid command
ER002: Parameter error
BT-LH910G Side
1
N.C.
2
TXD
3
RXD
4
DSR
5
GND
6
DTR
7
CTS
8
RTS
9
N.C.
:
Data
ETX (03h)
Command
ETX (03h)
Data
ETX (03h)
ETX (03h)