Usb-C; Real Time Clock (Rtc); Serial In Terminal Connection - Panasonic TH-98SQE1W Operating Instructions Manual

Table of Contents

Advertisement

The maximum amount of the Displays that can be
connected by using daisy-chaining function may differ
depending on the source device's capacity. The image
that will be displayed in all Displays will be defined by
the source device. For example, to be able to stream
4 different FHD images, the source device should be
capable of supporting this operation.
Note: It is recommended to use a DisplayPort certified cable
for connection.
When using cascade-connected Displays, it is recommended
to set the DisplayPort Stream Setting as SST on all Displays
in SST operation mode.
For proper operation in MST operation mode make sure your
source device is MST compliant. If your source device is a
computer check the specifications of its graphic card to ensure
MST compatibility. When using daisy-chained Displays, it is
recommended to set the DisplayPort Stream Setting as
MST on all Displays in MST operation mode.

USB-C

Multiple protocols and power delivery up to 5V@1.5A
are supported via USB-C receptacle on your display.
USB Type-C features are compatible with the devices
that meet the USB-Type-C-Specification. 4K video
stream (if the source supports DisplayPort alternate
mode), USB 2.0 data transmission and 5V@1.5A
power delivery are supported through the USB-C
connection that handle the plug orientation.
Note: It is recommended to use Electronically Marked USB-C
to USB-C cable for video stream over Type-C connection.
Also e-marked USB-C to USB-A cable can be used for data
transmission.

Real Time Clock (RTC)

Your Display has an RTC. It is used to maintain the
real date and time information for a period of time if
the energy supply is interrupted by separating the
Display from the mains or by a power blackout. In this
case the Display will use the date and time information
stored in RTC.
• All time sources are able to override RTC date/time.
• Display tries to connect to the NTP server period-
ically (6 hours after last update) to get the current
date and time information. If the Display successfully
gets these informations from the NTP server, it
updates itself and RTC with the received date and
time information. If the NTP server update fails, the
Display uses RTC time and date to update itself.
• The RTC battery provides power to the integrated
real-time clock and the calendar. Without any
external power source, RTC is able to function for
a minimum of 14 days.
• If RTC is used as time source, manual date-time set
is enabled from Date/Time option in the Settings>
System menu.
Serial IN Terminal
Connection
The SERIAL terminal conforms to the RS-232C
interface specification, so that the Display can be
controlled by a computer which is connected to this
terminal.
Note: Additional computer and cables shown are not
supplied with this set.
(Female)
D-sub 9p RS-232C Straight cable (commercially
available)
PC
Note : Select the RS-232C straight cable for
communication used for connecting SERIAL terminal
and computer according to the computer you are
using.
Pin assignments and signal names for SERIAL
Terminal
1
6
(Male)
(Male)
2
3
4
5
8
7
9
English - 39 -