Initialize Nvm - Sharp AR-C360P Service Manual

Hide thumbs Also See for AR-C360P:
Table of Contents

Advertisement

5.1.2.6 Initialize NVM

This self-diagnosis is used to initialize the nonvolatile memory.
1.
Continue to press the [MENU+] and [MENU-] keys until "NV-RAM INITIAL" appears at the
top row of the display, and the system is in the self-diagnosis (Level 1) mode. The [MENU+]
key = Increment Test Item / the [MENU-] key = Decrement Test Item.
2.
When the [ENTER] key is pressed, the Table No. to be initialized appears at the bottom
row of the display. There are 3 tables initialized. Press the [MENU+] and [MENU-] keys
until the applicable Table No. appears. The [MENU+] key = Increment Table No. / the
[MENU-] key= Decrement Table No.
NV-RAM INITIAL
INITIAL 1
Note
Do not use INITIAL 2.
3.
When the [ENTER] key is pressed, the "NV-RAM INITIAL" display blinks at the top row
of the display. Press it for 10 consecutive seconds to initialize all items indicated in Table
5-3.
4.
Press the [BACK] key to end the test. (Returns to state 1)
Item to Initialize
K-DRUM UNIT
Y-DRUM UNIT
M-DRUM UNIT
C-DRUM UNIT
FUSER UNIT
TR BELT UNIT
K-DISTNR
Y-DISTNR
M-DISTNR
C-DISTNR
DISTNR CNT
DISTNR BOX TNR CNT
Rev. 1
Table 5-3 NV-RAM Initial
Unit
Initial Setting
IMAGES
0
Total number of revolutions since the ID unit for each
color has been installed.
IMAGES
0
IMAGES
0
IMAGES
0
PRINTS
0
Total number of revolutions since the fuser unit has
been installed.
IMAGES
0
Total number of revolutions since the belt unit has
been installed.
-
0
-
0
Quantity of each color of toner to be discarded
-
0
-
0
-
0
Quantity of toner discarded in toner disposal
Quantity of toner discarded in toner disposal or for
-
0
correction (e.g., color cast, color misregistration, and
density)
Detail
108 /

Advertisement

Table of Contents
loading

Table of Contents