AUDIO BATTERY TEST
When you first turn the unit from OFF to ON, the automatic battery test circuit is activated. You
will hear an audio tone, the volume and duration relating to the battery strength. When the
battery test is no longer heard, the 9 V battery needs to be replaced. See "Installing the Battery"
in the GETTING STARTED section.
CHECK AND ADJUST THRESHOLD
Set the MODE switch to AUTO, to be in the ALL METAL MODE with retune. Check that the
threshold is set correctly to a faint hum. Adjust the threshold if it is not correct.
GROUND BALANCING
Ground Balancing is not a difficult procedure, but it is critical if you desire maximum depth and
stability. It is especially important if you are using the Outlaw in highly mineralized ground.
NOTE: No matter where you will be searching, or whether you will be operating in the ALL
METAL MODE or Discrimination MODE, make sure the detector is properly Ground Balanced
in the AUTO tune mode of ALL METAL first.
As shown in Figures 11 and 12 below, raise the searchcoil 6 to 8 inches above the ground,
level and parallel to the ground. You will lower the searchcoil quickly to ground level and return
back to the starting point 6 to 8 inches above the ground. This "pump" is designed to show the
ground to the Outlaw.