Etl Designation; Appliance Labels - STIEBEL ELTRON Accelera 220 E Operation And Installation Manual

Dhw heat pump water heater
Hide thumbs Also See for Accelera 220 E:
Table of Contents

Advertisement

OPERATION
Safety
CAUTION
!
Hydrogen gas is produced by this heater in a hot water
system that has not been used for a long period of time
(2 weeks or more). Hydrogen gas is extremely fl amma-
ble. To reduce the risk of injury under these conditions,
it is recommended that the hot water faucet be opened
for several minutes at the kitchen sink before using any
electrical appliance connected to the hot water system.
When hydrogen is present, there will probably be an
unusual sound such as air escaping through the pipe as
the water begins to fl ow. There should be no smoking or
open fl ame near the faucet at the time it is open.
Material losses
!
If you disconnect the appliance from the power supply, it
is no longer protected against frost.
 Do not interrupt the power supply to the appliance.
Material losses
!
Never cover this appliance. Covering the air intake or air
discharge leads to a reduced air supply. If the air supply
is restricted, the operational reliability of the appliance
cannot be guaranteed.
Material losses
!
Only operate the appliance when the DHW tank has been
fi lled.
Material losses
!
Keep the appliance installation room free from air con-
taminated with oil or salt and corrosive or explosive sub-
stances.
2.4

ETL designation

The ETL designation shows that the appliance meets all essential
UL and CAN/CSA requirements. This appliance conforms to:
- UL Standard 1995
- UL Standard 174
- CAN/CSA Standard C22.2 No.236-05
- CAN/CSA Standard C22.2 No.110-94
8
| Accelera® 220-300 E
2.5

Appliance labels

1. Type plate label for the Accelera 220 E
Accelera 220 E
Part number/code article:
Electrical/électrique
Voltage/tension:
Frequency/fréquence:
Breaker/disjoncteur:
P
(rated power input)/puissance nominale:
nmax
Maximum allowable ratings/courant nominal:
Protection class/indicie de protection:
Heat pump/pompe à chaleur:
P
(Air 107.6°F / Water 149°F):
N
Refrigerant/frigorigène:
Refrigerant charge/frigorigène poids de remplissage:
Max. operating pressure/max. pression de service:
Lock rotor current/puissance blockade:
MCA:
Rated compressor load/courant nominale du compresseur:
Motor fan/moteur de ventilateur:
DHW cylinder/DHW cylindre:
Backup heating element/chauffage d'appoint:
Max. operating pressure/max. pression de service:
Max. operating temperature/max. temperature de service:
Tank material/matériau réservoir:
Nominal capacity/capacité nominale:
Tank test pressure/contrôle de réservoir:
2. Condensate drain information label
Condensate
Condenso
Condensat
3. Hot water outlet location label
Hot Water Outlet
Salida de agua caliente
Sortie eau chaude
4. Cold water outlet location label
Cold Water Inlet
Entrada para agua fría
Entrée eau froide
5. Power connection information label
!Attention!
Must connect to
240 V, 15 A
Power supply
Disconect power supply
Double-pole
Before opening the cover
Circuit breaker
No.:#### / ######
285872-34892
233058
Conforms to UL STD. 1995
Conforms to UL STD. 174
Single phase 220-240 V
Certified to CAN/CSA STD. C22.2 No.236-05
50 / 60 Hz
Certified to CAN/CSA STD. C22.2 No.110-94
15 A
2200 W
2200 W, 9.17 A
IP 24
Stiebel Eltron Inc.
0.54 kW
R-134a
17 West Street
1.874 lb / 850g
West Hatfield, MA 01088, USA
348.1 PSI / 2,400 kPa
800.582.8423
15.3 A
info@stiebel-eltron-usa.com
14 A
2.5 A
24 W
Read the instructions carefully.
Tested for leaks.
1690 W
Lira attentivement la notice.
87 PSI / 600 kPa
Étanchéité testé.
168.8°F / 76°C
Steel
58.12 gal / 220 l
Made in EU/Fabriqué en UE
130.5 pSI / 900 kPa
311803-38055
311802-38055
www.stiebel-eltron-usa.com

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Accelera 300 e

Table of Contents