Connectors And Buttons; Hardware Overview - Axis Q1635 User Manual

Fixed network camera
Hide thumbs Also See for Q1635:
Table of Contents

Advertisement

AXIS Q1635 Fixed Network Camera

Hardware Overview

Important
If the Axis product is installed in an external camera housing, leave an unobstructed cylinder-shaped zone with Ø85 mm (3 3/8 in)
around the lens to enable lens movements within the housing.

Connectors and Buttons

For technical specifications, see page 73.
Network Connector
RJ45 Ethernet connector with Power over Ethernet (PoE).
NOTICE
TICE
NO
NO
TICE
Due to local regulations or the environmental and electrical conditions in which the product is to be used, a shielded network
cable (STP) may be appropriate or required. All cables connecting the product to the network and that are routed outdoors
or in demanding electrical environments shall be intended for their specific use. Make sure that the network devices
are installed in accordance with the manufacturer's instructions. For information about regulatory requirements, see
Electromagnetic Compatibility (EMC) on page 2 .
I/O Connector
Use with external devices in combination with, for example, tampering alarms, motion detection, event triggering, time lapse recording
and alarm notifications. In addition to the 0 V DC reference point and power (DC output), the I/O connector provides the interface to:
Digital output – For connecting external devices such as relays and LEDs. Connected devices can be activated by the
VAPIX® Application Programming Interface, output buttons on the Live View page or by an Action Rule. The output will
show as active (shown under System Options > Ports & Devices) if the alarm device is activated.
Digital input – An alarm input for connecting devices that can toggle between an open and closed circuit, for example:
PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes
active (shown under System Options > Ports & Devices).
Power Connector
2-pin terminal block for power input. Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either a rated
output power limited to ≤100 W or a rated output current limited to ≤5 A.
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q1615-eQ1615P3384-ve

Table of Contents