Toshiba UE3G2L036C61T Instruction Manual page 20

Uninterruptible power system single phase – 3.6/ 6/8/10 /14/18 kva /1600ep series
Hide thumbs Also See for UE3G2L036C61T:
Table of Contents

Advertisement

UPS Specifications (cont'd)
Capacity
Applications
Switches
Bypass Switch
Bypass Disable
Automatic Retransfer
User Interface
Real Time Clock
Schedule Operation
RUN/STOP Disable
Autostart
Remote ON/OFF
LED Display
LCD Screen
UPS Operation: 6 Keys
Buzzer Volume
Power Connections
Emergency Power Off
Remote Contacts
RS232 ASCII Interface
Mechanical Design
Enclosure
Size (HxWxD) Inches (max)
Paint System
Fan Panel
Battery System
Battery Replacement
Battery Packs
Battery Pack Size
(HxWxD)Inches(max)
Battery Pack Quantity
Battery Manufacturer
Battery Type
Toshiba's Part Number for
Battery Pack
(*)Input/output figures rated for 240 volts. Output ratings given for 0.85PF are only valid
when the input voltage is greater than 204 volts; otherwise, ratings given for 0.70PF are
applicable.
(**) Battery backup time may vary depending on the operating conditions and ambient
temperature at the installation site.
(***) An initial charge time of 24 hrs. is necessary to obtain proper battery performance level
before unit is placed in operation.
(****) At 6600 ft (2000 m) above sea level, output capacity should be derated by 3%.
TOSHIBA
STANDARD MODELS
10kVA (8.5kW)*
Generator compatibility
Static switch <1/4 cycle (50Hz:5ms/60Hz:4.16ms)
Factory or authorized service center selectable only
Provided (can be disabled from front panel)
Standard, Minimum 3 days memory backup during power loss
Schedule ON/OFF operation of UPS using communication software
UPS has option for UPS to start automatically when AC is applied
Standard, external terminal
4 LED's indicating input/output condition, warning and battery operation
16 characters x 2 lines
Run/Stop, Set/Monitor, Shift/Select, Del/(page down), Reset/(page up)
Low, High, Mute; Selectable by keypad
Hard wire (Standard)
Standard (Terminal contacts only)
Standard (INV, BYP, BATT, LB, AC, FLT)
Standard
Enclosure of unit made from sheet metal meeting NEMA1 and UL Type 1
28.25 x 13 x 33.5
Powder coating.
Panel mounted on back of UPS to allow for easy replacement of fans
without turning UPS off.
Slide out battery packs accessible from front of UPS, factory or authorized
service center serviceable only
Designed for battery acid leakage containment with (6) batteries per pack.
4
Enersys
NPX-35
51896
21
14kVA (11.9kW)*
39.1 x 17.5 x 34.8
5 x 7.3 x 18.2
8
18kVA (15.3kW)*
39.1 x 17.5 x 34.8
8