Connecting Of Power Supply - LockMaster DSC 600 User Manual

Sliding gate opener
Table of Contents

Advertisement

Connecting Of Power Supply

The power supply cord should be at least H05R1V-F, 3×0.75mm2.
Connect the live wire, neutral wire and earth wire to the "L",
"N" and "PE" terminal respectively. It is strongly recommended
that an emergency stop switch is installed in the electrical
system which can be used in case of the remote control failure.
You can connect the switch by the following steps:
1. Cut off the wire which has been connected between terminal
4 and 5 in factory to deactivate the existed short circuit of
terminal 4 and 5.
2. Solder the two wires to the terminals of the switch respectively.
NOTE: The power supply cord is not included in the package.
NOTE: Make sure a residual current circuit breaker with a 30mA
threshold is fitted before the power supply mains.
NOTE: The protection class of the emergency stop switch should be at least IP44.
10