4
Align the (red) arrow labels on the
image drum with the arrows on the
device, and gently insert into the slot
and push in firmly all the way while
being careful not to touch the green
cylinder with your hands.
Note
⿟ Be careful not to touch or scratch the image drum
(green cylinder).
5
Close the front cover.
Reference
⿟ Model C941/ES9541dn requires the Spot Color kit to be set.
For details, see the "Separate Volume Spot Color Guide".
„ Set the transfer roller unit.
1
Lift the exit unit opener (
out the exit unit.
2
Raise the lock levers (blue) at both ends
of the transfer roller unit installation
location of the exit unit.
- 41 -
Installing the Device
), and pull
1
2
3
4