Appliance Data; Installation Requirements; Room Sizing; Site Requirements - Firecraft L23G Installation And User Instructions Manual

Fl05 - fl06 flueless gas fire
Table of Contents

Advertisement

2.0

APPLIANCE DATA

Gas Group
Inlet Pressure
Max Energy Input
Max Gas Rate
Min Energy Input
Pilot Energy Input
Burner Pressure High
Main burner flow restrictor
Oxypilot
Gas Inlet Connection
Ignition
Spark Gap
Please see Data Badge affixed to appliance for current data.
This appliance is for use only with the gas type, and at the pressure stated on the appliance Data Badge.

INSTALLATION REQUIREMENTS

3.0
If the appliance is to be sited near a disused natural draught flue it is recommended that the old flue
should be partially sealed off to prevent draughts, however some ventilation will be required to prevent
condensation. The appliance is designed to be wall mounted. It is possible to install the appliance onto
certain types of combustible materials - see section entitled 'Clearances to combustible materials'.
In the event that the fire is sited near a disused or unserviceable fireplace served by a natural draught
flue, any existing under grate draught device should be sealed off to prevent loss of heat or creation of
draughts. The passageway into the flue should be partially sealed to prevent excessive draughts, however
some ventilation will be required in the old flue to prevent condensation and dampness. Advice should be
sought from your local building control officer.
3.1

ROOM SIZING

The room size should be a minimum of 23m 3 (e.g. 10'2" x 10'2" x 8') to allow adequate circulation of air
and ensure the correct operation of the fire. This volume may include adjacent spaces but these spaces
must not be separated by a door. To calculate a room size in cubic metres (m 3 ) divide the room volume
in cubic feet (ft 3 ) by 35.3.

SITE REQUIREMENTS

4.0
This appliance is designed to be wall-hung. Do not recess any part of the appliance into the wall.
This Appliance may be installed in any room in a home, however there are exceptions, and the appliance
may not be used in the following rooms;
· Bedrooms - or areas which are mainly used for sleeping.
· Bathrooms - or areas where large amounts of steam are likely to be generated.
Installation in living rooms is common, however other rooms such as kitchens, dining rooms and hall-
ways are permitted, providing a suitable natural gas supply is available, and rooms sizing and ventilation
requirements are strictly adhered to (see section 4.1).
The appliance is designed to be versatile, and as such will operate correctly when exposed to normal gen-
tle draughts experienced within the home. It is not recommended, however that the appliance be installed
in areas where it is likely to be exposed to persistent strong draughts, that may be generated by outside
doors or windows, air vents etc. It is recommended that the appliance should not be installed within 500mm
of any air vent.
Low
G20 Natural Gas CAT I2H
20 mbar
Gross
2.0 kW
Net
1.8 kW
0.20 m3/h
Gross
1.3 kW
Net
1.15 kW
Gross
166 W
Net
150 W
17.3 mbar. (+/-0.75 mbar). Hot
17.0 mbar. (+/-0.75 mbar). Cold
6.3 mbar. (+/-0.25 mbar). Hot
6.0 mbar (+/-0.25 mbar). Cold
Stereo 1.03mm (1/4" BSP)
SIT/Bray 9082
8mm inlet restrictor elbow
Piezo spark
4.0 mm (± 1.0mm)
2