3.0
VENTILATION AND ROOM SIZE (continued)
The room size should be a minimum of 23m
and ensure the correct operation of the fire. This volume may include adjacent spaces but these spaces
must not be separated by a door. To calculate a room size in cubic metres (m
in cubic feet (ft
be used in a room without some form of background heating present.
4.0

OPERATING INSTRUCTIONS

The pilot is visible behind the left hand side of the burner.
The control knob is located on the lower right hand side of the
outer case. It is of a spherical design and is marked as shown in
the diagram to the right.
Push in and turn the control knob to the SPARK position, and hold
there for a few seconds. Continue turning anti-clockwise through
the spark click to the PILOT light position, ensuring the pilot has
lit. If not, return the knob clockwise, and repeat.
When the pilot lights after the spark, keep the knob depressed for
approximately ten seconds. Now release the knob and the pilot
should stay alight. If the pilot is extinguished during use, wait
three minutes before repeating the ignition procedure.
To achieve the HIGH setting, push the control knob in slightly and
continue turning anti-clockwise to the high position. The main
burner should light after a few seconds. To decrease the setting to LOW, turn the control knob clockwise
to the low setting.
To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to the
pilot position and release. To turn the fire OFF, keep the knob pressed in, return to the off position and
release.
COMBUSTION MONITORING SYSTEM
5.0
This fire is fitted with a combustion monitoring safety device (ODS). If the appliance shuts down during use
for no apparent reason then several reasons may be suspected. If a door or window has been opened cre-
ating a draught, then pilot disturbance could be the problem and removal of the draught should resolve
this. The appliance can then be re-lit in accordance with the previous section.
If pilot disturbance is not the cause, then the ODS safety system may be in operation. Switch the appliance
OFF, call in your installer to check the appliance and ventilation. Remedial work must be carried out as
required. DO NOT allow the appliance to be used until the appliance and installation is passed as safe. If
the pilot continues to be extinguished, you must call your installer to check the operation of the complete
appliance.
6.0
CLEANING
Before carrying out any of the following operations, ensure that the appliance is OFF and completely cold.
INNER GLASS PANEL -
er. Test on a small area first.
GLASS FACIA PANEL - This should only be cleaned using a suitable glass cleaner. Test on a small area first.
PAINTED AREAS - These can be cleaned using a dry cloth.
STAINLESS STEEL AREAS - These can either be cleaned using a proprietary stainless steel metal cleaner or
baby oil. Test on a small hidden part of the stainless steel before cleaning. Always clean in the direction of
the grain.
7.0
SERVICING
The appliance should be checked on an annual basis to ensure it is working safely. The frequency of
service will depend on usage, but MUST be carried out at least once annually. Servicing must be carried
out by a competent person, such as a CORGI registered installer. The Installation instructions carry full
servicing details for the use of the installer.

LIST OF SPARE PARTS

8.0
PART NO.
FB/F960002
FT003155/1
FB/F780081
As our policy is one of continuous improvement and development , we hope therefore you will understand we must
retain the right to amend details and/or specifications without prior notice.
3
) by 35.3. This appliance is intended as a secondary source of heat only and should not
This can be cleaned with a suitable glass cleaner, or propriety ceramic hob clean-
ITEM
Glass door assembly
Gas valve
Catalyst
3
(e.g. 10'2" x 10'2" x 8') to allow adequate circulation of air
PART NO.
FT/F730023
TRAY055
FB/F940136
3
3
) divide the room volume
'OFF' position
'SPARK' position
'LOW' position
'HIGH' position
ITEM
Pilot assembly
Burner tray
Seal kit for Catalyst
DO005730/0