Firecraft Superior Standard BBV-42RMN Homeowner's Care And Operation Instructions Manual

Firecraft Superior Standard BBV-42RMN Homeowner's Care And Operation Instructions Manual

Advertisement

Quick Links

RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone.
Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
WH Report No. J99025850
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
HOMEOWNER'S CARE AND
OPERATION INSTRUCTIONS
STANDARD SERIES
42" B-VENTED GAS APPLIANCES
P/N 725,007M REV. N/C 08/2000
MODELS
Millivolt Models
BBV-42RMN
BBV-42RMP
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout autre
appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une
odiur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où
vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
L'installation et service doit être exécuté par un
qualifié installeur, agence de service ou le fournisseur
de gaz.
Electronic Models
BBV-42REN
BBV-42REP
1

Advertisement

Table of Contents
loading

Summary of Contents for Firecraft Superior Standard BBV-42RMN

  • Page 1 HOMEOWNER'S CARE AND OPERATION INSTRUCTIONS STANDARD SERIES 42" B-VENTED GAS APPLIANCES P/N 725,007M REV. N/C 08/2000 MODELS Millivolt Models Electronic Models BBV-42RMN BBV-42REN BBV-42RMP BBV-42REP RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR WH Report No.
  • Page 2: Table Of Contents

    CONGRATULATIONS! Provide adequate clearances around air open- ings and adequate accessibility clearance for service and proper operation. Never obstruct In selecting this SUPERIOR B-vented gas appliance you have chosen the finest and most the front openings of the appliance. dependable fireplace to be found anywhere. A beautiful, prestigious, alternative to a wood burning fireplace.
  • Page 3: Operation/Care Of Your Appliance

    Millivolt appliances may be fitted at time of Carbon Monoxide Poisoning: Early signs of OPERATION AND CARE OF YOUR manufacture with either a Honeywell millivolt carbon monoxide poisoning are similar to APPLIANCE gas control valve or as SIT millivolt gas control the flu with headaches, dizziness and/or nau- valve.
  • Page 4 2. When lit for the first time, this appliance will emit a slight odor for an hour or two. This is due to the “burn-in” of internal paints and lubricants used in the manufacturing process. 3. Keep lower control compartment clean by vacuuming or brushing at least twice a year.
  • Page 5: Damper & Outside Air Controls

    WARNING: FIREPLACES EQUIPPED WARNING: DAMPER MUST BE IN OPEN WARNING: DO NOT OPERATE THE OUT- WITH OPTIONAL ACCESSORY DOORS POSITION WHEN APPLIANCE MAIN SIDE AIR ACTUATOR UNLESS A COM- SHOULD BE OPERATED ONLY WITH THE BURNER IS OPERATING. PLETE OUTSIDE AIR VENT SYSTEM HAS DOORS FULLY OPEN OR FULLY CLOSED BEEN INSTALLED WITH YOUR APPLI- ( FIGURE 4 ).
  • Page 6: Maintenance

    Maintenance The appliance and venting system should be thoroughly inspected before initial use and at least annually by a qualified service techni- cian. Proper maintenance and use will require more frequent, less extensive inspections and servicing by the homeowner. Generally, annual inspections should be per- formed by a qualified service technician.
  • Page 7: Maintenance Schedule

    Maintenance Schedule Annually (Before the onset of the Burning Season) Maintenance Task Accomplishing Person Procedure Inspecting/Cleaning Burner, Logs Qualified Service Technician Inspect valve and ensure it is properly operat- and Controls ing. Check piping for leaks. Vacuum the control compartment, fireplace logs and burner area.
  • Page 8: Log And Rockwool Placement

    Logs and Rockwool Placement WARNING: LOGS GET VERY HOT AND WILL REMAIN HOT UP TO ONE HOUR AFTER GAS SUPPLY IS TURNED OFF. HANDLE ONLY WHEN LOGS ARE COOL. TURN OFF ALL ELECTRICITY TO THE APPLIANCE BEFORE YOU INSTALL GRATE AND LOGS. WARNING: THIS APPLIANCE IS NOT MEANT TO BURN WOOD.
  • Page 9: Wiring Diagrams

    WIRING DIAGRAMS Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics found on pullout labels located within the control compartment attached to the gas control valve. Two Millivolt wiring diagrams are provided here, one each for both Honeywell and SIT equipped systems.
  • Page 10: Lighting Instructions - Millivolt

    LIGHTING INSTRUCTIONS – MILLIVOLT FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted with a piezo •...
  • Page 11 INSTRUCTIONS D’ALLUMAGE – MILLIVOLT POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE AVERTISSEMENT : SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE. A.
  • Page 12: Lighting Instructions - Electronic

    LIGHTING INSTRUCTIONS — ELECTRONIC FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. When lighting the appliance, follow these instructions •...
  • Page 13 INSTRUCTIONS D’ALLUMAGE — ELECTRONIC POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE AVERTISSEMENT: SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE. A.
  • Page 14: Troubleshooting Guide - Millivolt

    TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in the “ON” position. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A.
  • Page 15: Troubleshooting Guide - Electronic

    TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM Note: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION...
  • Page 16: Warranty

    WARRANTY REPLACEMENT PARTS When ordering repair parts, always give the following information: A complete parts list is found at the end of this Your gas appliance is covered by a limited 1. The model number of the appliance. twenty year warranty. You will find a copy of manual.
  • Page 17: Accessory Components

    ACCESSORY COMPONENTS INDICATOR SIGNAL LIGHT ON/OFF BUTTONS Decorative Volcanic Stone 80L42 FDVS Bag of Rockwool 88L53 Decorative Volcanic Stone The decorative volcanic stone, Model FDVS, RCK-S can be used to enhance the look of your appli- Remote Control System (Standard) 75L66 RCK-S ance.
  • Page 18: Replacement Parts List

    REPLACEMENT PARTS LIST — MILLIVOLT Natural Propane DESCRIPTION Part No. Qty. Part No. Qty. Gas Fireplace Assembly – – – – Firescreen 161108 161108 Rod, Screen 498168 498168 Refractory, Side LB-98313A LB-98313A Refractory, Rear LB-98314A LB-98314A Refractory Access Panel LB-97223 LB-97223 Refractory, Base (Left) LB-97271...
  • Page 19 REPLACEMENT PARTS NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
  • Page 20 FireCraft Technologies reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2000 by FCT 4325 Artesia Avenue •...

Table of Contents