Service Instructions
The 944 Series Relief Valve has a tungsten carbide seat (9) and should not require frequent replacement. The tungsten carbide ball
(7), in normal service, will last a long time because it rotates and wears evenly. If there is leakage, replace the ball.
IMPORTaNT: Open the adjustment knob (1) to full counterclockwise position before unthreading valve seat (9) from valve
body (4).
If the valve stem (3) is rotated inwardly with the ball removed, the Teflon O-ring (5) may require replacement. If there has been leakage
from the valve stem, the Teflon O-ring should be replaced.
IMPORTaNT: The valve stem stop (6) must be unthreaded from the valve stem (3) with a socket screwdriver, then the valve
stem can be threaded out of the valve body.
IMPORTaNT: all non-moving threads must be assembled with Loctite sealant, Titan part # 426-051.
3
2
1
1
2
3
3
4
5
6
4
5
6
840-209 Bleed Line assembly with valve
ITEM
PaRT
NO.
1
944-028
2
103-101
3
103-117
4
538-030
7
ITEM
PaRT
NO.
1
944-024
2
944-020
3
944-004
4
944-026
5
761-715
6
945-003
7
944-904
ITEM
PaRT NO. DEScRIPTION
NO.
1
0509762A
3
7
2
103-575
103-585
3
103-679
4
420-070
5
103-125
6
103-119
7
0509760A
26
DEScRIPTION
NO.
Valve, bleed
Bleed line assembly
Tube
Hose assembly
944-028 Bleed valve assembly
DEScRIPTION
NO.
Knob assembly
Valve body
O-ring
Valve stem stop
Ball, T.C.
Gasket, copper
Valve seat
103-807 Siphon valve assembly
103-808 55 Gallon Siphon assembly
Rock catcher
Tube
Tube (55 gal. siphon ass'y)
Hose clamp
Hose
Spring
Clip
Adapter
© Titan Tool Inc. All rights reserved.
QTY.
1
1
QTY.
1
1
1
1
1
1
1
QTY.
1
1
1
2
5'
1
1
1