MK Diamond Products MK-377 Owner's Manual Operating Instruction & Parts List page 11

Hide thumbs Also See for MK-377:
Table of Contents

Advertisement

MK-377 SAW
WARNING
The "drip loop" is that part of the cord below the level of the recep-
tacle, or the connector, if an extension cord is used. This method of
positioning the cord prevents the travel of water along the power cord
and coming in contact with the receptacle.
If the plug or receptacle gets wet, DO NOT unplug the cord. Discon-
nect the fuse or circuit breaker that supplies power to the tool. Then
unplug and examine for presence of water in the receptacle.
WARNING
Use only extension cords that are intended for outdoor use. These extension cords are
identified by a marking "Acceptable for use with outdoor appliances; store indoors while
not in use." Use only extension cords having an electrical rating not less than the rating of
the product. Do not use damaged extension cords. Examine extension cords before using
and replace if damaged. Do not abuse extension cords and do not yank on any cord to dis-
connect. Keep cords away from heat and sharp edges. Always disconnect the extension
cord from the receptacle before disconnecting the product from the extension cord.
WARNING
To reduce the risk of electrocution, keep all connections dry and off the ground. DO NOT
touch the plug with wet hands.
WARNING
Use of under sized extension cords result in low voltage to the motor that can result in motor
burnout and premature failure. MK Diamond warns that equipment returned to us showing
signs of being run in a low voltage condition, through the use of undersized extension cords
will be repaired or replaced totally at the customer's expense. There will be no warranty claim.
To choose the proper extension cord,
• Locate the length of extension cord needed in the table below.
• Once the proper length is found, move down the column to obtain the correct AWG
size required for that length of extension cord.
EXTENSION CORD LENGTH
115V
25'
Nameplate
Amperes
250V
50'
0 - 5
16
5.1 - 8
16
8.1 - 12
14
12.1 - 15
12
15.1 - 20
10
50'
75'
100'
100'
150'
200'
16
16
14
16
14
12
14
12
10
12
10
10
10
10
11
SAFETY
Drip Loop Information
150'
200'
300'
400'
12
12
10