Pll F & Lpf F Final Adjustment (Vc-288 Board) - Sony DCR-TRV940 Adjustment Manual

Hide thumbs Also See for DCR-TRV940:
Table of Contents

Advertisement

DCR-TRV940/TRV940E/TRV950/TRV950E
5. PLL f
& LPF f
Final Adjustment (VC-288 board)
0
0
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified value
Note 1: Check that the data of page: 0, address: 10 is "00".
Adjusting method:
Order Page Address Data
1
0
01
2
3
01
3
3
02
4
3
03
5
0
01
Note 2: If check is NG, the machine is defective.
Note 3: If bit value of bit2, bit3, bit4, bit5 or bit6 is "1", adjust-
ment has errors. For the error contents, see the follow-
ing table. (For the bit values, refer to "6-4. SERVICE
MODE", "4-3. 3. Bit value discrimination".)
Bit value of page: 3,
address: 03 data
bit2 = 1 or bit 3 =1
bit4 = 1 or bit 5 =1
bit6 = 1
VTR stop
No signal
Displayed data of page: 3, address:
02 and 03
Adjusting remote commander
C
1F, 20, 22, 29
The data of page: 3, address: 02 is "00"
The data of page: 3, address: 03 is "00"
Procedure
01
30
Press PAUSE button.
Check the data changes to
"00" within 5 seconds.
(Note 2)
Check the data is "00".
(Note 2, 3)
00
Error contents
PLL f
fine adjustment is defective
0
PLL f
adjustment is defective
0
LPF f
adjustment is defective
0
6-60

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-trv950eDcr-trv940eHandycam dcr-trv950

Table of Contents