4. Overall Noise Level Check

Mode
Camera recording and playback
No signal: Insert a shorting plug in
Signal
the MIC jack
Audio left or right terminal of A/V
Measurement Point
jack
Measuring Instrument
Audio level meter
Below –45 dBs
Specified Value
(IHF-A filter ON, 20 kHz LPF ON)
Checking Method:
1) Insert a shorting plug in the MIC jack.
2) Record in the camera mode.
3) Playback the recorded section.
4) Check that the noise level is the specified value.

5. Overall Separation Check

Mode
Camera recording and playback
Signal
400 Hz, –66 dBs signal: MIC jack
<right> [left]
(Connect the MIC jack <left> [right]
to GND)
Measurement Point
Audio <left> [right] terminal of A/V
jack
Measuring Instrument
Audio level meter
Specified Value
Below –40 dBs (IHF-A filter ON)
< > : Left channel check
[ ] : Right channel check
Checking Method:
1) Input the 400 Hz, –66 dBs signal in the <right> [left] terminal
of the MIC jack only.
2) Record in the camera mode.
3) Playback the recorded section.
4) Check that the signal level of the audio output <left> [right]
terminal is the specified value.