DCR-TRV940/TRV940E/TRV950/TRV950E
8.
AWB Standard Data Input
Adjust the white balance reference at 3200K.
Subject
Adjustment Page
Adjustment Address
Note 1: "AWB Standard Data Input" is available only once after
the power is turned on. Turn the power off, then on again
if the adjustment is retried.
Note 2: Check that the data of page: 0, address: 10 is "00".
Note 3: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Switch setting
1) POWER ................................................................... CAMERA
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
1
0
01
2
6
01
3
6
01
4
6
02
Note 4: The adjustment data will be automatically input to page:
F, address: 2A to 2D.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
0
01
RadarW
RadarW
RadarW
RadarW
RadarW
Clear chart
(Color reproduction adjustment
frame)
F
2A to 2D
Procedure
01
11
Press PAUSE button.
0B
Press PAUSE button. (Note 4)
Check the data changes to
"01".
Procedure
00
Press PAUSE button.
00
9.
MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects
in low illuminance will not be produced (dark).
Subject
Adjustment Page
Adjustment Address
Note 1: Perform "AWB Standard Data Input" before this adjust-
ment.
Note 2: Check that the data of page: 0, address: 10 is "00".
Note 3: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Note 4: NTSC model: DCR-TRV940/TRV950
PAL model: DCR-TRV940E/TRV950E
Switch setting
1) POWER .................................................................. CAMERA
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADY SHOT (Menu setting) ..................................... OFF
Adjusting method:
Order Page Address Data
1
0
01
2
6
96
3
6
97
4
6
01
5
6
02
Note 5: The adjustment data will be automatically input to page:
F, address: 19.
Processing after Completing Adjustment:
Order Page Address Data
1
6
96
2
6
97
3
6
01
4
0
01
6-30
RadarW
RadarW
RadarW
Clear chart
(Color reproduction adjustment
frame)
F
19
Procedure
01
Set the following data
32: NTSC model
19: PAL model
00
6F
Press PAUSE button. (Note 5)
Check the data changes to
"01".
Procedure
00
00
00
Press PAUSE button.
00