Flange Back Check - Sony DCR-TRV940 Adjustment Manual

Hide thumbs Also See for DCR-TRV940:
Table of Contents

Advertisement

DCR-TRV940/TRV940E/TRV950/TRV950E
6.

Flange Back Check

Subject
Measurement Point
Measuring Instrument
Specified value
Note 1: Check that the data of page: 0, address: 10 is "00".
Switch setting
1) POWER ................................................................... CAMERA
Note 2: When the auto focus is ON, the lens can be checked if it
is focused or not by observing the data on the page: 1 of
the adjusting remote commander.
1 : 00 : XX
Preparations before adjustments:
1) Place the Siemens star 2.0 m from the front of the lens.
Checking method:
Order Page Address Data
1
6
40
2
6
41
3
4
5
0
03
6
1
7
6
21
8
9
Processing after Completing Adjustment:
Order Page Address Data
1
6
21
2
6
40
3
6
41
4
0
03
Siemens star
(2.0 m from the front of the lens)
(Luminance: 300 to 400 lux)
Check operation on monitor TV
Focused at the TELE end and WIDE
end
Odd: Focused
Even: Unfocused
Procedure
01
01
Shoot the Siemens star with
the zoom TELE end.
Turn on the auto focus.
0F
Check that the lens is
focused. (Note 2)
10
Shoot the Siemens star with
the zoom WIDE end.
Observe the TV monitor and
check that the lens is
focused.
Procedure
00
00
00
00
6-28