User and Installation Instructions
Electric Auto-Fill Water Boilers
EB3F, EB4F, EB6F, EB6TF
IS339 ECN3539

Advertisement

Table of Contents
loading

Summary of Contents for Lincat EB3F

  • Page 1 User and Installation Instructions Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539...
  • Page 2: Table Of Contents

    Thank you for purchasing this Lincat product. With correct use and careful maintenance as described in these instructions, your Lincat product will give years of trouble free use. We produce over 450 different items of catering equipment and our range is constantly being extended and improved.
  • Page 3: Safety Information

    Remove all plastic coatings and clean the unit before use. • Ensure that the electrical supply cable is not damaged. If it is, it must be replaced by Lincat Ltd or by qualified personnel. • Always disconnect the unit from the electricity supply before servicing.
  • Page 4: Technical Specification

    Power Rating Net weight net Ambient temperature 5 to 30 Water inlet pressure 1 to 8 ACCESSORIES Wall mounting kit for EB3F, EB4F BR49 Wall mounting kit for EB6F, EB6TF BR50 Replacement filter cartridge FC02 INSTALLATION The boiler must be installed on a horizontal surface in a location where it can be supervised by trained personnel.
  • Page 5 EB4F The boiler is supplied with a bulkhead cable connector and must be fitted with 2.5mm 3-core cable.The supply end of the cable must be fitted with an all- pole disconnection isolator switch with a minimum of 3mm contact separation. For safety regulations the means of disconnection must always be accessible.
  • Page 6 Control panel Water dispensing tap Filter cartridge Drip tray and cover Serial plate IS339 ECN3539...
  • Page 7 OPERATION First use Switch on the mains water supply and the electricity supply Leave the boiler for 30 minutes to allow it to fill completely Drain off approximately 5 litres of water to remove any loose carbon particles from the filter. Regular operation The boiler starts automatically when the mains water supply is turned on.
  • Page 8 Press the power button to cycle through the values 35 to 60. Press the Fn button to select the required value Press the power button to exit. Standby If the boiler is to be left unused for a long period, the element can be turned off by pressing the power button.
  • Page 9: Cleaning

    The boiler is best descaled at the end of the working day to allow the descaling agent several hours to work. Lincat recommends its own descaling agent, available from Lincat spares department, part code MS19.
  • Page 10 Remove the outer and tank lids again and inspect the tank and level sensor housings for scale deposits. If necessary repeat the descaling process Drain and flush all descaling agent from the tank completely as follows Remove the two screws behind the drip tray that secure the lower front panel Connect a hose from the overflow pipe to a bucket and turn the service valve to drain the remainder of the water from the tank...
  • Page 11: Diagnostic Messages

    DIAGNOSTIC MESSAGES The control panel displays messages and information that can help with fault diagnosis. Before calling for service, draw off a litre of water, clear the fault code by pressing the Fn button and turn the boiler off and on again at the mains supply.
  • Page 12: Service Information

    From serial plate (beside dispensing tap) • Serial number Lincat reserve the right to carry out any work under warranty during normal working hours, Monday to Friday, 08:30 am to 17:00 pm. GUARANTEE This unit carries a comprehensive UK twelve-month warranty. The guarantee is in addition to, and does not diminish your statutory or legal rights.
  • Page 13 This page intentionally left blank IS339 ECN3539...