  • Page 1 User and Installation Instructions Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461...
  • Page 2: Table Of Contents

    We produce over 450 different items of catering equipment and our range is constantly being extended and improved. Find out more about Lincat products from your local distributor or direct from us.
  • Page 3: Safety Information

    SAFETY INFORMATION To prevent injury to yourself or your staff, and to avoid damaging the product, please read and follow the safety precautions below before setting up and using the unit: • Remove all plastic coatings and clean the unit before use. •...
  • Page 4: Delivery Checklist

    WARNING The unit must be installed on a solid concrete / brick wall by a qualified fitter. Lincat does not accept any responsibility for the safety of any unit not installed this way. Use the template provided, IS436, to mark the position of the 3 mounting holes. Drill the wall and insert suitable wall plugs.
  • Page 5: Electrical Installation

    ELECTRICAL INSTALLATION For safety regulations the plug or means of disconnection must always be accessible. This boiler must be earthed. Check that the voltage of your electricity supply corresponds to the voltage shown on the serial plate. The boiler is supplied with a terminal block suitable for flexible wires upto 6mm .
  • Page 6: Operation

    OPERATION Layout of components 1. Power Button 2. Fn Button 3. Filter 4. Knock-out for water 5. Knock-out for power 6. Grommet for tank drain 7. Overflow pipe IS435 ECN3461...
  • Page 7 First use Switch on the mains water supply and the electricity supply. Leave the boiler for 15 minutes to allow it to fill completely. Drain off approximately 3 litres of water to remove any loose carbon particles dislodged from the filter. Regular operation The boiler starts automatically when the mains electrical supply is turned on.
  • Page 8: Cleaning

    Filter replacement The “FILTER” display shows the estimated remaining life in the current filter cartridge. When the filter needs replacing, a reminder message is displayed. This is followed by the change filter screen. The boiler can be used without a filter but scale may build up more quickly and water taste may be affected.
  • Page 9: Maintenance

    The boiler is best descaled at the end of the working day to allow the descaling agent several hours to work. Lincat recommends its own descaling agent, available from Lincat spares department, part code MS19.
  • Page 10 DETAIL A Flush out the tank with clean water. When empty replace the drain plug and replace the cover. Replace the tank lid, ensuring that the gasket is sealing the top of the tank correctly. Fit the outer cover and turn on the boiler. IS435 ECN3461...
  • Page 11: Diagnostic Messages

    DIAGNOSTIC MESSAGES The control panel displays messages and information that can help with fault diagnosis. Before calling for service, draw off a litre of water, clear the fault code by pressing the Fn button and turn the boiler off and on again at the mains supply. If the fault persists call the service department for advice.
  • Page 12: Service Information

    Type number • Serial number Lincat reserve the right to carry out any work under warranty during normal working hours, Monday to Friday, 08:30 am to 17:00 pm. GUARANTEE This unit carries a comprehensive UK twelve-month warranty. The guarantee is in addition to, and does not diminish your statutory or legal rights.