Errors - Nedap PowerRouter Installation Manual

Solar inverter
Hide thumbs Also See for PowerRouter:
Table of Contents

Advertisement

PowerRouter • Solar Inverter • Installation manual
7.5

Errors

i
Check www.PowerRouter.com for the latest version of the errorlist.
Error
Level
Explanation
P027-H
Hard
A grid error has occurred
P028-H
P029-H
G025-H
P058-H
Hard
After a firmware update one of the
modules has an incompatible
firmware version
P073-H
Hard
Last grid connection self test (italy
only) has failed
P081-H
Hard
The installation wizard or
installation tool failed to write the
anti-islanding settings to the
PowerRouter
P092-H
Hard
The PowerRouter configuration is
incorrect
G034-H
S019-H
P098-H
Hard
The firmware in the PowerRouter
does not match the hardware
G036-H
S021-H
P100-S
Soft
There was too much load
variation during the sensor test
P105-S
Soft
The PowerRouter needs a 1-
phase or 3-phase sensor to
operate in the selected scenario.
This sensor was not detected.
P106-S
Soft
The connection between the
PowerRouter and the 3-phase
sensor has been lost, or the 3-
phase sensor has no power.
Action
Restart the system (section 7.6.1)
The system should recover from the error after the
restart
Contact your dealer if this error occurs frequently
Contact your dealer for the correct firmware
package
Update the firmware of the system with the correct
version
Restart the system (section 7.6.1)
Restart the self test, succesful completion of the self
test clears this error
Restart the system (section 7.6.1)
Run the installation tool or install wizard again
Contact your dealer if this error occurs frequently
Contact your dealer if this error occurs
Contact your dealer if this error occurs
Turn off the loads connected to the same phase as
the PowerRouter
Restart the system (section 7.6.1)
Make sure the connection of the 1-phase or 3-phase
sensor is correct and in the right position. For
detailed information see the related section in this
manual.
Restart the system (section 7.6.1)
Check the connection between the PowerRouter
and the 3-phase sensor.
Check the power connection of the 3-phase sensor.
Restart the system (section 7.6.1),
7 Troubleshoot
EN
35

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PowerRouter and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF