1
Camera Installation
Shipping Dimensions
Environmental
IP rating (dust and water ingress)
Operating temperature range
Storage Temperature range
Humidity
Shock
Vibration
Approvals
427-0073-12-12 Version 120
14.375"(L) x 7.375"(W) x 7"(H)
IP66 & IP67
-50 °C to 70 °C (-58 °F to 158 °F) continuous
-40 °C to 70 °C (-40 °F to 158 °F) cold start
-55 °C to 85 °C (-67 °F to 185 °F)
0-95% relative
IEC 60068-2-27 10 g shock pulse
with a 11ms half-sine profile
MIL-STD-810F
FCC Part15, Subpart B, Class B,
EN 55022 Class B, EN 50130-4,
EN60950
May 2015