Dip Switch Settings And Locations; Control Board Dip Switch; Feed Head Board Dip Switch - Lincoln Electric POWER WAVE SVM173-A Service Manual

Lincoln electric welding system user manual
Table of Contents

Advertisement

A-10

DIP SWITCH SETTINGS AND LOCATIONS

DIP switches on the PC boards allow for custom con-
figuration of the Power Wave. Access the DIP switch-
es as follows:
WARNING
ELECTRIC SHOCK CAN KILL.
• Do not touch electrically live parts or
electrodes with your skin or wet cloth-
ing.
• Insulate yourself from the work and
ground.
• Always wear dry insulating gloves.
• Turn off power at the disconnect switch.
• Remove the top four screws securing the front access
panel.
• Loosen, but do not completely remove, the bottom
two screws holding the access panel.
• Open the access panel, allowing the weight of the
panel to be carried by the bottom two screws. Make
sure to prevent the weight of the access panel from
hanging on the harness.
• Adjust the DIP switches as necessary. Using a pen-
cil or other small object, slide the switch left for the
ON position or to the right for the OFF position, as
appropriate.
• Replace the panel and screws and restore power.
CONTROL BOARD
(LOCATED IN
CONTROL BOX
BEHIND CASE
FRONT)
DEVICENET/
GATEWAY
BOARD
BANK S1
(LOCATED
BANK S2
BEHIND
FRONT
COVER)
FRONT
COVER
LEFT
INSTALLATION

CONTROL BOARD DIP SWITCH:

switch 8

FEED HEAD BOARD DIP SWITCH:

switch 7
switch 8
FEED HEAD
BOARD
(LOCATED IN
CONTROL
BOX BEHIND
CASE FRONT)
CASE FRONT
OPENING IN
CASE FRONT
TO ACCESS
CONTROL
BOX
RIGHT
POWER WAVE 455M/MSTT
switch 1 = reserved for future use
switch 2 = reserved for future use
switch 3 = reserved for future use
switch 4 = reserved for future use
switch 5 = reserved for future use
switch 6 = reserved for future use
switch 7 = reserved for future use
switch 8 = work sense lead
work sense lead
off
work sense lead not connected
on
work sense lead connected
switch 1 = reserved for future use
switch 2 = reserved for future use
switch 3 = reserved for future use
switch 4 = reserved for future use
switch 5 = reserved for future use
switch 6 = reserved for future use
switch 7 = negative polarity switch
switch 8 = high speed gear
electrode polarity
off
positive
on
negative
wire drive gear
off
low speed gear
on
high speed gear
A-10