11. Unplug and label leads X5, X6, X7, X8, and X9.
These leads have connectors near the trans-
former which can be disconnected.
12. Disconnect the output choke lead from the posi-
tive capacitor bank buss using two 1/2 in. open
end wrenches.
13. Remove the other output choke lead from the
positive output terminal using a 1/2 in. wrench.
13. Remove all cable ties, wire mounts, and any har-
ness type that could get in the way during trans-
former removal using wire cutters and screw
driver.
TROUBLESHOOTING AND REPAIR
MAIN TRANSFORMER AND OUTPUT CHOKE
REMOVAL AND REPLACEMENT (continued)
POWER MIG 255C
14. Remove the four nuts and washers mounting the
transformer to the floor of the machine using a
1/2 in. wrench.
15. Carefully remove the main transformer and choke
assembly.
16. Reassemble the main transformer and choke
assembly in the reverse order.