Active Scr Rectifier Assembly Test - Lincoln Electric POWER MIG SVM170-A Service Manual

Lincoln electric welding system user manual
Table of Contents

Advertisement

F-21
STATIC SCR RECTIFIER ASSEMBLY TEST (continued)
FIGURE F.4 — LOCATION OF
NEGATIVE
CAPACITOR
BANK BUSS
BAR
6. Disconnect leads X2 and X3 (braided
copper strap) from the negative capaci-
tor bank buss bar using a 1/2 in. open
end wrench. See Figure F.4.
7. Separate leads X2 and X3 from the
negative capacitor bank buss bar. Be
sure there is no electrical contact.
NOTE: DO NOT DISASSEMBLE THE SCR
RECTIFIER HEAT SINK ASSEMBLY.
8. Test for high or infinite resistance from
the anode to the cathode of SCR 1
using an analog ohmmeter. See Figure
F.5.
TROUBLESHOOTING AND REPAIR
LEADS X2 AND X3.
LEADS X2 AND X3
CONNECTION
POWER MIG 255C
FIGURE F.5 — SCR 1 TEST POINTS.
9. Test for high or infinite resistance from
the cathode to the anode of SCR 1 by
reversing the meter leads. See Figure
F.5.
a. If a high or infinite resistance is indi-
cated for both tests 6 and 7, the
SCR 1 is not "shorted".
b. If a low resistance is indicated in
either tests 6 or 7, the SCR is faulty.
Replace the SCR assembly.
10. Repeat steps 6 and 7 to test SCR 2.
11. Reconnect leads X2 and X3 (braided
copper strap).
12. Reconnect plugs J5 and J6.
13. If this test did not identify the problem,
or to further test the SCR, go to the

Active SCR Rectifier Assembly Test.

F-21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power mig 255c

Table of Contents