Lincoln Electric NA-5N Service Manual page 99

Automatic welding systems
Table of Contents

Advertisement

F-46
VOLTAGE BOARD TRANSFORMER TEST
TEST PROCEDURE
1. Remove all input power to the NA-5.
2. Using the 5/16" nutdriver open the
control box PC board access door.
3. Locate the voltage board. See
Figure F.3
TROUBLESHOOTING & REPAIR
FIGURE F.3 VOLTAGE BOARD LOCATION
NA-5
(Continued)
4. Remove the molex type plugs from
the voltage board.
5. Using the phillips head screwdriver
remove the voltage board from the
control box.
6. Locate the transformer and test
points on the voltage board. See
Figure F.4
F-46
VOLTAGE
BOARD

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Na-5sNa-5nfNa-5sfNa-5