Lincoln Electric NA-5N Service Manual page 21

Automatic welding systems
Table of Contents

Advertisement

A-14
FIGURE A.13 – CONNECTION OF NA-5 TO DC-1000 OR DC-1500.
THE DIAGRAM SHOWS ELECTRODE CONNECTED POSITIVE. TO CHANGE POLARITY, TURN POWER OFF, REVERSE THE ELECTRODE AND WORK LEADS AT THE
POWER SOURCE, POSITION THE POSITIVE-NEGATIVE SWITCH ON THE POWER SOURCE TO CORRESPOND TO THE POLARITY OF THE ELECTRODE CABLE CONNECTION.
REFER TO NA-5 OPERATING MANUAL FOR REQUIRED NA-5 CONTROL BOX POLARITY CONNECTIONS.
N.A. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS.
N.B. EXTEND LEAD 21 USING #14 OR LARGER INSULATED WIRE PHYSICALLY SUITABLE FOR THE INSTALLATION. AN S-16586-[ ] REMOTE VOLTAGE-SENSING WORK LEAD
IS AVAILABLE FOR THIS PURPOSE. CONNECT IT DIRECTLY TO THE WORK PIECE KEEPING IT SEPARATE FROM THE WELDING WORK CABLE CONNECTION TO
WORK PIECE. FOR CONVENIENCE, THIS EXTENDED #21 LEAD SHOULD BE TAPED ALONG THE WELDING WORK CABLE.
N.C. TAPE UP BOLTED CONNECTION.
N.D. CONNECT THE NA-5 CONTROL CABLE GROUND LEAD TO THE FRAME TERMINAL MARKED
MUST BE PROPERLY GROUNDED.
N.E. IF USING AN OLDER AUTOMATIC CONTROL CABLE WITH LEADS 75, 76, 77; CONNECT LEAD 75 TO #75 ON TERMINAL STRIP, CONNECT LEAD #76 TO #74 ON TERMINAL
STRIP, CONNECT LEAD #77 TO #73 ON TERMINAL STRIP.
N.F. CONNECT THE JUMPERS ON THE NA-5 VOLTAGE BOARD AS FOLLOWS: CONNECT RED JUMPER TO PIN "S". CONNECT WHITE JUMPER TO PIN "B".
N.G. SET THE DC-1000 OR DC-1500 CONTROLS AS FOLLOWS: SET THE CONTROL SWITCH TO "OUTPUT CONTROL REMOTE".
FOR SUBMERGED ARC PROCESSES, SET THE MODE SWITCH TO "C.V. SUBMERGED ARC". FOR OPEN ARC PROCESSES, SET THE MODE
SWITCH TO "C.V. INNERSHIELD"
N.H. FOR PROPER OPERATION, THE ELECTRODE CABLE MUST BE SNUGGED UNDER THE CLAMP BAR ON THE LEFT SIDE OF THE NA-5 CONTROL BOX.
N.J. TERMINALS #73 AND #74 WERE NOT PRESENT ON DC-1500 MACHINES BELOW CODE 8294. THESE EARLIER CODE MACHINES ARE NOT SUITABLE FOR
USE WITH THE NA-5.
N.K. ALTERNATIVE 500 AMP POSITIVE TERMINAL CONNECTION PROVIDED ON DC-1000 MODELS ABOVE CODE 9500 ONLY.
N.L. ALTERNATE SUBMERGED ARC MODE AVAILABLE FOR IMPROVED ARC STABILITY IN HIGH CURRENT, LARGE PUDDLE, SLOW TRAVEL PROCEDURES BY MAKING
SPECIAL CONNECTIONS ON BOTH DC-1500 AND NA-5.
ON DC-1500 CONTROL BOARD (G-1530-2 AND SUPERSEDING) REMOVE RED AND BLUE JUMPERS FROM "FR" PINS AND RECONNECT TO CORRESPONDING "SR" PINS.
ON NA-5 VOLTAGE BOARD (G-1556-1 AND SUPERSEDING) WHITE JUMPER MUST BE CONNECTED TO PIN "D".
NA-5 PIN "D" CONNECTION MAY ALSO BE USED FOR SOME PROCEDURES ON DC-1500 WITHOUT CONTROL BOARD JUMPERS, DC-1500 WITH CONTROL BOARD
JUMPERS ON "FR" PINS OR DC-1000.
INSTALLATION
POWER SOURCE
P
CONTROL
CABLE
BOLT TO CABLES FROM
NA-5 WIRE CONTACT
ASSEMBLY
CONNECT TO WORK
NEAR THE POWER SOURCE TERMINAL STRIP. THE POWER SOURCE
CLEVELAND, OHIO U.S.A.
NA-5
A-14
INPUT CABLE PLUG

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Na-5sNa-5nfNa-5sfNa-5

Table of Contents