Digital Meter - Lincoln Electric NA-5N Service Manual

Automatic welding systems
Table of Contents

Advertisement

F-75
DIGITAL METER AND METER PC BOARD REMOVAL AND REPLACEMENT
DIGITAL METER REMOVAL
PROCEDURE
1. Using the phillips head screwdriver
remove the four screws from the
meter bezel. See Figure F.12
2. Carefully remove the bezel assem-
bly.
3. Carefully remove the meter shield
assembly.
MOUNTING
INSULATOR
DIGITAL
METER
TROUBLESHOOTING & REPAIR
FIGURE F.12 METER BEZEL AND SCREW LOCATIONS
4. Using the 5/16" nutdriver, remove
the two nuts, screws and lockwash-
ers holding the digital meter to the
cover assembly.
5. Carefully remove the digital meter.
METER SHIELD
ASSEMBLY
METER SHIELD
NA-5
F-75
METER BEZEL

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Na-5sNa-5nfNa-5sfNa-5

Table of Contents