B-14
EXPLANATION OF PROMPTING
AND ERROR MESSAGES
Display
Prompt or Error
Acc
Displayed on Voltage display, indicates WFS
display is showing acceleration setting, "1" to
"5" (See "Acceleration Selection" in this
section).
OFF
Displayed on WFS and voltage displays; indi-
cates limits for WFS or voltage are off for the
displayed procedure. (See "Maximum and
Minimum Limits Setting Modes" in this
section).
SEC
Displayed on WFS display, indicates Voltage
display is showing a Timer setting in sec-
onds. (See "Display Control Keys" in this
section)
GLP
Displayed on WFS display, indicates that the
Grounding Lead Protector circuit was activat-
ed due to excessive current flow into the
wire feeder frame. When the GLP circuit is
activated the wire feeder is disabled (the trig-
ger output to the power source is opened up,
the motor is stopped, and the gas solenoid is
turned off). To resume normal operation,
release the trigger, make sure that the elec-
trode is not touching the wire feeder frame,
and then either press a key on the keypad or
close the trigger. (See "Grounding Lead
Protector" in this section)
Cld
Displayed on Voltage display when Cold
Feed Forward or Cold Feed Reverse Key is
pressed, or Cold Feed Trigger mode is
selected. Indicates wire is fed "cold" (no
weld voltage) at the speed indicated on the
WFS display. (See "Operation Keys" and
"Trigger Mode Selection" in this section).
---
Displayed on Voltage or WFS displays with
RUN-IN selected, indicates setting will match
those set for Weld Voltage and Wire Feed
Speed (See "Display Control Keys" in this
section).
HXX
Displayed on WFS display, indicates wire
feed overload. XX indicates time remaining
in seconds before unit resets automatically.
(See "Wire Feed Overload Protection" in
this section and "Avoiding Wire Feeding
Problems" in the MAINTENANCE section).
OPERATION
Er
EEPROM error. Usually occurs at power-up.
Indicates one or more of the recalled settings
is out of acceptable limits. Press any key to
return to normal operation. Be sure to check
all voltage, wire feed speed, acceleration and
timer settings before you proceed.
DH-10
B-14