CB1200-I Pellet Insert
12. Door Gasket Inspection
Frequency: Prior to heating season
By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off
b. To inspect the door rope (gasket), open the door and
see that the door rope extends approximately 1/8 inch
(3mm) to 3/16 inch (9.5mm) from the door rope chan-
nel.
c. It should show signs of compaction all the way around
the door where the rope contacts the face of the appli-
ance. Confi rm there are no air leaks.
13. Cleaning Exhaust Blower - Requires No Lubrication
Frequency: Yearly or as needed
By: Quality Service Technician/Homeowner
Task:: Contact your local dealer.
14. Cleaning Convection Blower - Requires No
Lubrication
Frequency: Yearly or as needed
By: Qualifi ed Service Technician
Task: Contact your local dealer.
15. Soot and Fly Ash: Formation & Need for Removal
in Exhaust Venting System.
Frequency: Yearly or more frequently depending on
ash build-up.
By: Qualifi ed Service Technician/Homeowner
Be sure the appliance is allowed to cool, has been unplugged
and the exhaust blower is off.
The products of combustion will contain small particles of fl y
ash. The fl y ash will collect in the exhaust venting system
and restrict the fl ow of the fl ue gases.
At start-up if there is incomplete combustion, or if there is a
shutdown or incorrect operation of the appliance it will lead
to some soot formation. This will collect in the exhaust vent-
ing system.
The venting system may need to be cleaned at least once a
year or more often depending upon the quality of your fuel
or if there is a lot of horizontal pipe sections. Ash will build
up more quickly in the horizontal sections.
Page 36
16. Preparing Firebox for Non-Burn Season
Frequency: Yearly
By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b. Remove all ash from the fi rebox and vacuum thoroughly.
c. Paint all exposed steel, including cast-iron.
• Use the Touch-Up paint supplied with the appliance;
or,
• Purchase paint from your local dealer.
• Must use a high-temperature paint made specifi -
cially for heating appliances.
7014-188C