Filling The Container; Mistblowing - Stihl SR 340 Instruction Manual

Hide thumbs Also See for SR 340:
Table of Contents

Advertisement

Available languages

Available languages

Checking metering unit
:
Place the machine on the ground.
:
Remove the baffle screen and
pressure pump.
:
Fill the container with water up to 10
liter mark.
:
Set the metering knob to "6"
:
Start the machine.
:
Hold the spray tube horizontally, run
the engine at full throttle, spray the
contents of the container down to
the 5 liter mark and note the time
taken.
The time required to spray 5 liters fluid
should be between 140 and 170
seconds.
In case of deviations:
:
Check the metering unit for
contamination and clean it if
necessary.
:
Check engine setting and correct if
necessary.
If no there is no improvement, contact
your dealer for assistance.
SR 340, SR 420

Filling the Container

:
Stand the machine on a level
surface.
:
Close the stop cock.
:
Fill up with thoroughly mixed spray
solution – do not exceed maximum
level of 13 liters (arrow).
1
:
The gasket (1) in the cap must
always be lubricated with grease.
:
Fit the cap and screw it down tightly.
English / USA

Mistblowing

:
Always use full throttle when
mistblowing.
:
Stop cock must be fully open while
mistbllowing – do not vary the flow
rate via the stop cock.
Different baffle screens enable the
shape of the spray jet to be varied.
Tapered baffle screen
Spray is finely atomized – short, broad
and dense spray pattern.
Deflector baffle screen
Diverts spray jet at an angle – for under-
leaf treatment of low-growing crops.
25

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Sr 420

Table of Contents