Filling The Container - Stihl SR 430 Instruction Manual

Hide thumbs Also See for SR 430:
Table of Contents

Advertisement

Available languages

Available languages

6
5
N
Rotate the nozzle (4) until the
lugs (5) are covered.
N
Pull the nozzle (4) off the blower
tube (6).
Converting back to misblowing mode
The conversion is carried out in the
reverse sequence.
Fitting the hose
N
Push the hose with clamp (2) over
the stub on the control handle.
N
Use pliers to squeeze the hose
clamp together (2) until the retaining
strip engages and locks.
SR 430, SR 450

Filling the Container

4
1
N
The gasket (1) in the cap must be in
good condition, lubricated with
grease and clean.
N
Stand the machine on a level
surface.
Mistblowing
2
N
Close valve lever (1) for solution
feed.
N
Pour thoroughly mixed spray
solution into the container through
the strainer.
Do not exceed maximum fluid level of
14 liters (arrow).
1
N
Fit the cap and tighten it down
firmly.
Dusting and spreading mode –
SR 450 only
N
Close the metering lever (1).
English
1
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sr 450

Table of Contents