4
Conveyor
Speed
(mm/sec)
PackTrack
Start Input
Number
Start Input
Active Level
Transmission
Edge
Distance
from PS
Line to
Tx Line
64
This parameter is available only when the Physical Encoder is
disabled. It defines the constant speed of the conveyor in mm/sec.
Refer to section 5.6 for physical PackTrack installation procedures.
Select an input from the drop-down list to define the number of
the input starting the reading phase.
Select Active Open or Active Closed from the drop-down list to
define the active state of the input.
Active Open: The input is active when there is no current
flowing through IN pins. The input from the trigger source
is normally closed. The scanner goes into trigger mode
when the input source is opened.
Active Closed: The input is active when current flows
through IN pins. The input from the trigger source is
normally opened. The scanner goes into trigger mode
when the input source is closed.
Select Trailing or Leading from the drop-down list to define the
signal edge of the stop input used by the scanner as reference for
ending the reading phase:
Trailing: The reading phase ends when the pack has
completely passed by the stop input.
Leading: The reading phase ends as soon as the stop
input detects the front edge of the pack.
Enter the distance along the Y axis from the PS (photoelectric
sensor) to the TX Line (transmit).