DC 6V
NETWORK PORT
(RJ-45)
RESET

Table 3: BASIC DEFINITIONS OF THE DP715 LEDS PATTERN

LEDs
POWER LED
Indicates Power. Remains green when power is connected, and orange when handset is
connected for charging.
NETWORK
Indicates Access to the Network. Remains ON while there is Access to the Network
REGISTERED
Indicates if the SIP accounts are registered
CALL
Indicates status of active calls.

Table 4: ADVANCED DEFINITIONS OF THE DP715 LEDS PATTERN

Pattern
Condition
Number
LED-01
Device has normal power
LED-02
Handset is placed on base with battery to charge
LED-03
Power Error: Power is removed from the device
LED-04
Power supply with improper voltage is plugged in
LED-05
Device has normal LAN connection and has obtained an
IP address
LED-06
Link Down
Note : This is the default state while the device is booting.
LED-07
Link Up but DHCP error
LED-08
Link Up but PPPoE error
LED-09
All configured SIP accounts are registered
LED-10
SIP accounts are in the process of registering
LED-11
Device is booting, application has not started.
LED-12
No account is configured on DP715
LED-13
Registration Error - ANY SIP account experiences
registration failure.
LED-14
Call is active. Any DECT handset is in an active call with
an external line.
LED-15
No active call.
LED-16
DECT Error
LED-17
VMWI
LED-18
Boot up
LED-19
Factory reset
Firmware version 1.0.0.31

Table 2: DEFINITIONS OF THE DP715 CONNECTORS

Power adapter connection.
10/100Mbps RJ-45 port toconnect to the network.
Factory Reset button: Press for 7 seconds to reset factory default settings.
DP715/DP710 User Manual
LED
LED Behavior
POWER
GREEN ON
POWER
ORANGE ON
POWER
POWER
Blink ( 0.5s on/ 0.5s off )
NETWORK
NETWORK
Blink (1s on/ 1s off).
Blink ( 0.25s on/ 0.25s
NETWORK
NETWORK
Blink ( 0.5s on/ 0.5s off )
REGISTERED
REGISTERED
Blink ( 1s on/ 1s off )
REGISTERED
REGISTERED
Blink ( 0.5s on/ 0.5s off -
REGISTERED
05s on/ 2s off )
CALL
Blink ( 0.5s on/ 0.5s off )
CALL
5 sequence of Blink
CALL
(0.25s on/0.25s off) + 3s
Blink (0.25s on/ 0.25s off -
CALL
0.25s on/ 0.25s off - 0.25s
on/ 0.75s off)
ALL
GREEN ON
GREEN ( 0.25s on/0.25s
ALL
off – 0.25s on/0.75s off )
OFF
ON
off )
ON
OFF
OFF
OFF
off
Page 10 of 56

Advertisement