Sharp FO-90 Service Manual page 24

Facsimile
Hide thumbs Also See for FO-90:
Table of Contents

Advertisement

FO-90RA
SW-J1 No. 7 Polling key
If this switch is set to 1, the last of Rapid key works as polling key.
SW-J1 No. 8 Reserved
Set to "0".
SW-J2 No. 1, No. 2 Reserved
Set to "0".
SW-J2 No. 3 ~ No. 5 Speaker Volume
Used to adjust sound volume from a speaker.
SW-J2 No. 6 Reserved
Set to "0".
SW-J2 No. 7 Saving energy start timing
Used to set the time between the machine's stand-by state (clock indi-
cation) after operation and saving energy mode.
It is possible to set the time to either 5 sec or 180 sec (default).
SW-J2 No. 8 Saving energy mode
Used to select whether to make the saving energy mode valid or not.
SW-J3 No. 1 ~ No. 3 Communication results printout
(Transaction report)
It is possible to obtain transaction results after each communication.
Normally,the switch is set (No. 1 : 0, No. 2 : 0, No. 3 : 0) so that the
transaction report is produced only when a communication error is en-
countered.
If No.1 was set to 0 and No. 2 to 1 and No. 3 to 0, the transaction report
will be produced every time a communication is done, even if the com-
munication was successful.
Setting No. 1 to 0 and No. 2 to 1 and No. 3 to 1 will disable this function.
No transaction report printed.
SW-J3 No. 4 Time format
When set to "0", 24hour time format is used.
When set to "1", 12hour time format is used.
SW-J3 No. 5 Date format
When set to "0", Day-Month-Year format is used.
When set to "1", Month-Day-Year format is used.
SW-J3 No. 6 ~ No. 8 Reserved
Set to "0".
SW-K1 No. 1 Entering diag mode by pressing SPEED key
A bit which is used in the production process only. When the SPEED key
is pressed, the switch is changed from the stand-by state to the diag
mode.
SW-K1 No. 2 ~ No. 8 Reserved
Set to "0".