3. 12. Entry data receive
This mode is used to receive the registered data from the other machine
and to make your machine register the received data. Before receiving
in this mode, it is necessary to set the other machine at the entry data
send mode.
After receiving is completed, the machine prints the following lists:
1. Telephone list data
2. Soft switch list
3. Junk fax number list
3. 13. Flash memory check
Data is written into and read from the flash memory to check the data
conformity. When the unit enters this mode, the check is started.
3. 14. Flash memory clear
Data in the flash memory is cleared (memory clear). When the unit en-
ters this mode, the check is started.
*Operation of hardware and signal in the flash memory check mode and
flash memory clear mode, and the result of check.
The result is announced by the buzzer beeps. The result of check is
printed.
Beeps
0 → No error
1 → Memory error
4. How to make soft switch setting
To enter the soft switch mode, press the following key entries in se-
quence.
Press FUNCTION
DATA No.
S F T SW-A1 = 0 0 0 0 0 0 0 0
S F T SW-A1 = 1 0 0 0 0 0 0 0
S F T SW-A1 = 1 0 0 0 0 0 0 0
S F T SW-A1 = 1 0 0 0 0 0 0 0
S F T SW-A1 = 1 0 0 0 0 0 0 0
S F T SW-A2 = 0 0 0 0 0 0 0 0
S F T SW-K1 = 0 0 0 0 0 0 0 0
9
8
7
1 2 3 4 5 6 7 8
The soft switch mode is terminated.
2 – 4
3. 15. Cutter aging
This mode is used to consecutively cut the recording paper about 10
mm long and to display the number of cutting times.
(The number of cutting times is cumulatively counted unless you ex-
ecute the memory clear.)
The operation is stopped in the following cases:
1. Hold down the stop key. (The cutter aging is stopped.)
2. No recording paper. (The cut operation is stopped.)
3. Recording paper jam. (The cut operation is stopped.)
START
START
Press FUNCTION key.
Press
key.
Press
key.
Bit1 - 8 are set.
Press
START
key during setting.
Soft SW-A2 - SW-K1 are set.
To finish the settings halfway between
SW-A1 and SW-K1, press the STOP
key. In this case, the setting being done
to the SW No. on display will be nullified
while settings done to the preceding
SW Nos. remain in effect.
When the COPY key is pressed, the
contents of soft switches are printed.

Advertisement