Outdoor Unit Does Not Operate - Toshiba RAS-13UKHP-E3 Service Manual

Ac split wall type
Table of Contents

Advertisement

RAS-13UKP-E3, RAS-10UKP-E3, RAS-07UKP-E3, RAS-13UKPX3, RAS-12UKPX3, RAS-10UKPX3, RAS-07UKPX3

9-5-3. Outdoor unit does not operate

Shut off the power supply
from AC outlet once and turn
it on after 5 seconds.
Does the OPERATION lamp blink?
YES
Does the power turn on by pushing
the [START/STOP] button of the
remote control?
YES
Is AC 220-240V supplied between
terminal block 1 -
YES
Is cable connection between indoor
and outdoor units correct?
YES
Check items as following procedure
in 9-5-4, 9-5-5, 9-5-6
NO
NO
NO
?
2
NO
See "Power can not be turned on".
See "Power can not be turned on".
Relays (RY01) or IC31
or IC30 is failure.
Correct cabling between indoor
and outdoor units.
− 61 −
FILE NO. SVM-04004
Replace the
P.C. board.