Installation Diagram Of Indoor And Outdoor Units - Toshiba RAS-13UKHP-E3 Service Manual

Ac split wall type
Table of Contents

Advertisement

8-2. Installation Diagram of Indoor and Outdoor Units

Before installing the
wireless remote control
• With the remote control cover
open, load the batteries supplied
correctly, observing their
polarity.
2
2 Wireless remote control
2
2
2
Cover
3
3 Batteries
3
3
3
13 series
A
600 mm
B
100 mm
5
Zeolite filter
6
Bioenzyme filter
8
2
Wireless remote
control
07,10 series
400 mm
45 mm
Hook
1
Installation
plate
Shield
pipe
Pan head wood screw
4
Remote control holder
Vinyl tape
Apply after
carrying out a
drainage test.
Saddle
Extension
drain hose
(Option:
RB–821SW)
− 41 −
FILE NO. SVM-04004
For the rear left and left
piping
Wall
Insert the cushion between
the indoor unit and wall,
and tilt the indoor unit for
better operation.
Do not allow the drain hose
to get slack.
Cut the piping hole
sloped slightly
Make sure to run the drain
hose sloped downward.
The auxiliary piping can be
connected the left, rear left,
rear right, right, bottom right
or bottom left.
Right
Rear right
Rear left
Bottom right
Bottom left
Insulate the refrigerant
pipes separately with
insulation, not together.
6 mm thick heat resisting
polyethylene foam
Left

Hide quick links: