Ras-10Ukhp-E3 / Ras-10Uah-E3 - Toshiba RAS-13UKHP-E3 Service Manual

Ac split wall type
Table of Contents

Advertisement

5-2. RAS-10UKHP-E3 / RAS-10UAH-E3

Cooling
0.39 m
Heating
(Connecting pipe)
Æ9.52
O.D.:9.52 mm
P
Packed valve
(Æ9.52)
Heating
Cooling
4-way valve
Heating Cooling Compressor
Cooling
Heating
50Hz
Standard
Heating
Overload*1
Low temperature
Standard
Cooling
Overload
Low temperature
Note
· Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
· During heating overload operation, a value for the high temperature limit control operation is included.
*1
Indoor unit
Evaporator
Cross flow fan
PH120T1-4C
Accumulator
Condenser
Propeller fan
Outdoor unit
Standar d
Surface temp. of heat
pressure P
exc hanger inter changing
(MPaG)
1.65
2.00 ~ 2.40
1.40
0.48
0.58
0.45
- 23 -
FILE NO. SVM-04004
T1
Packed valve
(Æ6.35)
Capillary tube
Æ1.5 x 900l
Refrigerant
R22 : 0.76 kg.
Mark (
) means check points of Gas Leak.
Fan speed
(indoor)
pipe T1 (°C)
40.0
High
52.0 ~ 59.0
Low
35.0
High
12.0
High
15.0
High
5.0
Low
0.49 m
(Connecting pipe)
Æ6.35
O.D.:6.35 mm
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
20/15
7/6
27/-
24/18
-10/-10
20/-
27/19
35/24
32/23
43/26
21/15
21/15