4-7. Outdoor Unit (RAS-13UAX3, RAS-12UAX3)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)

4-8. Outdoor Unit (RAS-10UA-E3)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Type
Output (Rated) 1100 W, 2 poles, 1 phase, 220 - 240 V, 50Hz
PH225X2C-4FT
Winding resistance (W)
(at 20°C)
Output (Rated) 30 W, 6 poles, 1 phase, 220 - 240 V, 50Hz
HF-240-30B
Winding resistance (W)
(at 20°C)
DS451155BPQC AC 450 V, 1.5 F
DS371356CPNB
AC 370 V, 35 F
Type
Output (Rated) 750 W, 2 poles, 1 phase, 220 - 240 V, 50Hz
PH102T1-4CH
Winding resistance (W)
(at 20°C)
Output (Rated) 20 W, 6 poles, 1 phase, 220 - 240 V, 50Hz
HF-240-20B or
Winding resistance (W)
SKF-240-20B
(at 20°C)
DS451155BPQC AC 450 V, 1.5 F
DS371256CPNB
AC 370 V, 25 F
- 20 -
FILE NO. SVM-04004
Specifications
C-R
2.35
Red-Black
245
m
m
Specifications
C-R
3.17
Red-Black
387.3 or 235.2 466.2 or 260.1
m
m
C-S
3.22
White-Black
388
C-S
5.18
White-Black