Specification Of Electrical Parts; Indoor Unit (Ras-24Nkhp-E); Outdoor Unit (Ras-24Nah-E) - Toshiba RAS-24NKHP-E Service Manual

Table of Contents

Advertisement

4. SPECIFICATION OF ELECTRICAL PARTS

4-1. Indoor Unit (RAS-24NKHP-E)

No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
Switchins transformer (T01)
4
Microcontroller
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Diode (DB01)
8
Capacitor (C02)
9
Fuse (F01)
10
Switching IC (IC01)
11
Varistor (R21, R22)
12
Resistor (R01)
13
Louver motor

4-2. Outdoor Unit (RAS-24NAH-E)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Solenoid coil
5
(for 4-way valve)
6
Thermo sensor
7
Magnetic contactor
8
Transformer
9
Microcontroller
10
Varistor (R73, R74, R86)
11
Fuse (F01)
Type
ICF-340-30-2
———
SWT-58A
TMP87CM40ANG
———
SS11V-R07190
D3SBA60
KMH450VNSN120M25C
TSCR
MA8920
15G561K
RF-5TK4R7
MP35EA12
Type
Output (Rated) 2200 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
PH400X3CS-4KT1 Winding resistance (Ω)
(at 20°C)
Output (Rated) 42 W, 4 poles, 1 phase, 220 – 240 V, 50 Hz
FG-240-42A-1
Winding resistance (Ω)
(at 20°C)
451405L
AC 450 V, 4.0µF
RS44B506K0218S AC 440 V, 50µF
VHV (STF)
AC 220 – 240 V
TE / TD
10 kΩ at 25°C / 50 kΩ at 25°C
220 − 240 V, 50 Hz
A35
TT-05
220 – 240 V
TMP47C840N
15G471K
470 V
MT3
T6.3 A, 250 V
− 11 −
FILE NO. SVM-05009
Specifications
DC 340 V, 30 W
10 kΩ at 25°C
DC 390 V, Secondary DC 15 V, 12 V, 7 V
6G60
10 kΩ at 25°C
19 mH, AC 0.7 A
4 A, 600 V
120µF, 450 V
T6.3 A, 250 V
5 A, 900 V
560 V
4.7 Ω, 5 W
Output (Rated) 2 W, 10 poles, 1 phase,
DC 12 V
Specifications
C-R
1.13
Red-Black
128
C-S
2.10
White-Black
126

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents