IDEAL VOGUE s15 Installation And Servicing page 41

System boiler
Hide thumbs Also See for VOGUE s15:
Table of Contents

Advertisement

41 MENU OPERATION
INsTALLER's DETAILs
The service required message which is displayed after 12
months can be customised to show the installer's telephone
number. To record your telephone number press ENTER and
the following screen will be displayed.
MENU
Vent System
Maximum Flow Temperature
Outside Sensor Slope
Fault Help
Press "-" until the following screen is displayed.
MENU
Maximum Flow Temperature
Installer's Details
Test Condensate Anti-Freeze
Set Zone 2 Flow Temperature
Press ENTER and a screen similar to the following will be
displayed.
Installer's Details
0
01482 498704
No. shown when service due
Press "+" and "-" to change the number and ENTER to accept.
Press ExIT twice to return to normal operation.
TEsT CONDENsATE ANTI-FREEzE
If Ideal's optional condensate anti-freeze kit has been fitted
to the boiler then to test operation press ENTER and the
following screen will be displayed.
MENU
Vent System
Maximum Flow Temperature
Outside Sensor Slope
Fault Help
Press "-" until the following screen is displayed.
MENU
Maximum Flow Temperature
Test Condensate Anti-Freeze
Set Zone 2 Flow Temperature
Press ENTER and the following screen will be displayed.
Condensate Anti-Freeze
ON for 5mins press
OFF
Only active if optional kit purchased
Press ENTER to activate.
Press ExIT twice to return to normal operation.
vogue system boiler -
INSTALLATION
INsTALLATION
Enter
Exit
Enter
Exit
Enter
Exit
Enter
Exit
Enter
Exit
Enter
Exit
Installation and Servicing
sET zONE 2 FLOW TEMPERATURE
When an outside sensor is connected to the boiler then a
second switched live is also connected, indicating cylinder
operation. To set the flow temperature target for cylinder
operation press ENTER and the following screen is displayed.
MENU
Vent System
Maximum Flow Temperature
Outside Sensor Slope
Fault Help
Press "-" until the following screen is displayed.
MENU
Test Condensate Anti-Freeze
Set Zone 2 Flow Temperature
Press ENTER and the following screen will be displayed.
70
°C
Set Zone 2 Flow Temperature
Press "+" & "-" to change the temperature to the require setting
and then ENTER. Press ExIT to return to normal operation.
PUMP MODULATION
The boiler is factory set for pump operation to give maximum
reliability. If the CH system has been fully balanced then
pump modulation can be increased to reduce electrical energy
consumption, to do so press ENTER and the following screen
is displayed.
MENU
Vent System
Maximum Flow Temperature
Outside Sensor Slope
Fault Help
Set Zone 2 Flow Temperature
Press "-" until the following screen is displayed.
MENU
Set Zone 2 Flow Temperature
Pump Modulation
Press ENTER and the following screen will be displayed.
Pump Modulation
Max
For minimum press
to save press
Press "-" to change the settings and then ENTER. Press Exit
to return to normal operation.
Enter
Exit
Enter
Exit
Enter
Exit
Enter
Exit
Enter
Exit
Enter
to save press
Exit
41