Initial Lighting - IDEAL VOGUE s15 Installation And Servicing

System boiler
Hide thumbs Also See for VOGUE s15:
Table of Contents

Advertisement

38 INITIAL LIghTINg

Legend
A. Boiler Status
B. Exit Button
C. Down Button
D. Up Button
E. Enter Button
F. Reset Button
G. CH Temperature Control
H. On / Off Switch
j. Burner On indication
K. Pressure Gauge
L. Boiler in Full Condensing Mode
M. CH Flow Isolating Valve
N. Gas Inlet Pressure Test Point
P. Gas Service Cock
R. CH Return Isolating Valve
PREPARATION FOR IgNITION
1. Check that the electrical supply is OFF.
2. Check that the system has been filled and that
the boiler is not air locked.
3. Ensure that the automatic air vent cap is open.
4. Refit the boiler front panel. Refer to Frame 45.
5. Check that the drain cock is closed and that the
CH (M & R) isolating valves are OPEN.
6. Move the On/Off switch (H) to the OFF position
7. Slacken the screw in the inlet pressure test
point (N) and connect a gas pressure gauge via
a flexible tube.
34
INSTALLATION
A
J
Press Enter
MENU
for
ON 60ºC
B
C
D
E
F
M
INITIAL IgNITION
1. Switch the electricity supply ON and check all internal and
external controls are calling for heat.
2. Move the On/Off Switch (H) into the On position. Set the
Boiler Temperature Control (G) to max. The boiler will now go
through its ignition sequence until the burner is established.
3. If the boiler has not lit, after 5 ignition attempts, the following
screen will be displayed.
Ignition Lockout
Check other Gas Appliances work
If not, re-instate gas supply
Reset boiler by pressing r
If fault persists contact installer
4. Reset the boiler and the ignition sequence will be repeated.
If reset occurs 5 times within 15 minutes then the following
screen will be displayed.
Too Many Resets
Contact Installer
If power is removed this will be reset.
vogue system boiler -
G
L
H
P
N
Installation and Servicing
K
2
1
3
0
4
R

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vogue s26Vogue s18Vogue s32

Table of Contents