IMPORTANT SAFETY INSTRUCTIONS

PCS200R Rack Installation
(also see pages 11 to 12)
• Wear a properly grounded, antistatic wrist strap
to avoid causing electrostatic (ESD) damage to
the PCS200R.
• Carefully slide the PCS200R into a standard
19-inch equipment rack.
• When mounting in the rack, make sure to use
the appropriate hardware. ALL FOUR MOUNT-
ING SCREWS MUST BE USED.
• This equipment is not designed to support
other devices. Do NOT stack other equipment
on the top of the PCS200R.
• Rear cabling must be dressed and supported
so that the weight of the cabling is not a strain
on the PCS200R connectors.
• MOUNTING OF THE EQUIPMENT IN THE
RACK SHOULD BE SUCH THAT A HAZARD-
OUS CONDITION IS NOT ACHIEVED DUE TO
UNEVEN MECHANICAL LOADING.
Rack-mount Considerations
A. Elevated Operating Ambient
If installed in a closed or multi-unit rack
assembly, the operating ambient temperature
of the rack environment may be greater than
room ambient. Therefore, consideration should
be given to installing the equipment in an
environment compatible with the maximum
ambient temperature (Tma) specified by the
manufacturer (see Specifications information
in this document).
206-4227
B. Reduced Air Flow
Installation of the equipment in a rack should
be such that the amount of air flow required
for safe operation of the equipment is not
compromised. To ventilate the system nor-
mally and avoid overheating, leave at least
1 inch (2.5 cm) on each side (including top
and bottom) of the PCS200R. Do NOT stack
other equipment on the top of the PCS200R.
Also, ensure that the unit's AC power adapter
is never stacked or bundled with other AC
power adapters. Each adapter should have
adequate ventilation and should be isolated
from other heat sources.
C. Circuit Overloading
Consideration should be given to the
connection of the equipment to the supply
circuit and the effect that overloading of the
circuits might have on overcurrent protection
and supply wiring.
D. Reliable Earthing
Maintain reliable earthing of rack-mounted
equipment. Particular attention should be
given to supply connections other than direct
connections to the branch circuit (e.g., use of
power strips).
E. Mains Outlet Earthing
The apparatus with Class I construction must
be connected to a mains socket outlet with a
protective earthing connection.