Description; Introduction; Certifications - REMEHA Gas 360 S Technical Instructions

Gas-fired boilers
Hide thumbs Also See for Gas 360 S:
Table of Contents

Advertisement

1 Introduction

Gas 360 S boilers are made of cast iron:
- with atmospheric gas burners
- with electronic ignition via the ignition burner for hot water central
heating
- with a useful output of between 54 and 117 kW
They are designed to be connected to a chimney.

2 Certifications

2.1
Introduction
It is CE approved under the following number : 0085AU0115
The boilers are in compliance with the EC directives:
- Royal Decree dated 8th January 2004
- 90/396/EEC Gas Appliance Directive:
Reference Standard : EN 297 ; EN 656
- 73/23/EEC Low Voltage Directive:
Reference Standard : EN 60.335.1
2.2
User country
User country
Category
Gas type
Distribution pressure (mbar)
The boilers leave the factory operating with H natural gas.
4

Description

ES
HU
II
II
2H3P
2H3P
G20
G31
G20
G31
20
37
25
50
Remeha Gas 360 S
The figure given after Gas 360 S indicates the number of sections
which make up the boiler.
Gas 360 S boilers are delivered with a K control panel. They can be
fitted with an optional RC4 and RC5 control unit (master-slave control
unit options).
- 89/336/EEC Electromagnetic Compatibility Directive
Reference Standard : EN 50.081.1 ; EN 50.082.1 ; EN 55.014
- 92/42/EEC Efficiency Directive **
Gas fired condensing boiler
- Type B11
(8 sections): This model is factory-fitted with a flue gas
BS
anti-overflow thermostat.
- Type B11 (10 to 14 sections): These models can be fitted with the
optional flue gas anti-overflow thermostat.
GB
II
2H3P
G20
G31
20
37
,
20/07/05 - 300005180-001-A