Service Indicator Error Codes - Invacare Leo Owner's Operator And Maintenance Manual

Hide thumbs Also See for Leo:
Table of Contents

Advertisement

Service Indicator Error Codes

FLASH DESCRIPTION
Battery Low
1
Low Battery Fault
2
High Battery Fault
3
Current Limit Time-out
4
Park Brake Fault
5
Throttle OONAPU
6
Speed Pot Fault
7
Motor Voltage Fault
8
Other error
9
Push/Rollaway Fault
10
Part No. 1163141
SECTION 6—MAINTENANCE AND TROUBLESHOOTING
SCOOTER STATUS
Scooter continues to
drive
Scooter stops driving
Scooter stops driving
Scooter stops driving
Scooter stops driving
Scooter stops driving
Scooter stops driving
Scooter stops driving
Scooter stops driving
Scooter stops driving
17
MEANING
The batteries are running low.
• Recharge the batteries.
The batteries have run out of charge.
• Recharge the batteries.
Battery voltage is too high. This may occur if
overcharged &/or traveling down a long slope.
• If traveling down a slope, reduce your speed to
minimize the amount of regenerative charging.
• Turn the scooter off and on again.
• If the battery charger is connected, disconnect
it from the scooter.
• Check the battery and associated connections
and wiring.
The motor has been exceeding its maximum cur-
rent rating for too long. This may be due to a
faulty motor.
• Check the motor and associated connections
and wiring. Contact your Invacare dealer.
• Turn the scooter off, leave for a few minutes
and turn back on again.
Either a park brake release switch is active or the
park brake is faulty.
• Check the park brake and associated connec-
tions and wiring.
• Ensure any associated switches are in their cor-
rect positions.
• Contact your Invacare Dealer.
The Throttle is out of neutral when turning the
controller on.
• Ensure the throttle is in neutral when turning
the controller on.
• The Throttle may require re-calibration. Con-
tact your Invacare Dealer.
The throttle, speed limit pot, SRW or their asso-
ciated wiring may be faulty.
• Check the throttle and speed pot and associ-
ated connections and wiring. Contact your Invac-
are Dealer.
The motor or its associated wiring is faulty.
• Check the motor and associated connections
and wiring. Contact your Invacare Dealer.
The controller may have an internal fault.
• Check all connections & wiring. Contact your
Invacare Dealer.
The scooter has exceeded the Push or Rollaway
speed limits.
• Turn the scooter off and then on again.
Leo Scooter

Hide quick links:

Advertisement

Table of Contents
loading