Se c tion 1: Sy s t e m Int ro du c ti on
1.1

Specifications

Downloading Software Support
• PC1565 v2.4ZD uses DLS-3 v1.3 and higher.
Flexible Zone Configuration
• Six fully programmable zones
• System expandable to 32 zones using:
up to 8 keypad zone inputs and/or
up to 32 wireless zones with the PC5132 wireless
expansion module
12 zones using zone doubling
• 38 access codes: one master code, one maintenance
code, two duress codes, two supervision codes and 32
general access codes
• 27 zone types; 8 programmable zone attributes
• Normally closed, single EOL and double EOL zone wiring
• 32 wireless zones with the PC5132 Wireless Receiver
Audible Alarm Output
• 700mA Supervised Bell Output (current limited at 3 amps),
12V
DC
• Steady or Pulsed Output
EEPROM Memory
• Does not lose programming or system status on complete
AC and Battery failure
Programmable Outputs
• One programmable voltage output and one programmable
voltage output/input; 20 programmable options
• PGM1 = 300mA; PGM2 = 50mA
Powerful 1.5 Amp Regulated Power Supply
• 550 mA Auxiliary Supply, 12 V
• Positive
Temperature
replace fuses
• Supervision for loss of AC power, low battery
• Internal clock locked to AC power frequency
Power Requirements
• Transformer = 16.0 V
AC
• Battery = 12 volt 14 Ah minimum rechargeable sealed lead
acid battery
Remote Keypad Specifications
• Keypads available:
- PC5509 eight zone LED keypad
- LCD5501Z fixed message LCD keypad with zone input
- PC1555RKZ eight zone LED keypad with zone input
- PC5508Z eight zone LED keypad with zone input
- PC5516Z sixteen zone LED keypad with zone input
- PC5532Z thirty-two zone LED keypad with zone input
- LCD5500Z Alphanumeric keypad with zone input
• All keypads (except PC5509) have five programmable
function keys
• Connect up to eight keypads
• 4-wire (Quad) connection to Keybus
• Built in piezoelectric buzzer
DC
Coefficient
(PTC)
components
, 40VA
Digital Communicator Specifications
• Supports major communication formats including SIA and
Contact ID
• Event-initiated personal paging
• Three programmable telephone numbers
• Two account numbers
• Supports GSM1000 cellular communication
• Supports LINKS2X50 long range radio transmitter
• DTMF and pulse dialing
• DPDT line seizure
• Anti-jam feature
• Split reporting of selected transmissions to each telephone
number
System Supervision Features
The PC1565 continuously monitors a number of possible trou-
ble conditions including:
• AC power failure
• Fault by zone
• Tamper by zone
• Fire trouble
• Failure to communicate
• Low battery by zone (wireless)
• Module fault (supervisory or tamper)
False Alarm Prevention Features
• Audible Exit Delay
• Audible Exit Fault
• Communication Delay
• Urgency on Entry Delay
Additional Features
• Auto-arm at specified time
• Keypad-activated alarm output and communicator test
• All modules connect to the system via a four wire Keybus
up to 1000'/305m from main panel
• An event buffer which records the past 128 events with
both the time and date at which they occurred; buffer can
be printed using PC5400 serial interface module, or
viewed with the LCD5500Z keypad and DLS-3 software
• Supports the addition of the PC5132 wireless receiver for
integration of wireless devices
• Uploading and downloading capability
• Local downloading capability through the use of the
PC-LINK adaptor
• Added Keybus fault protection: clock and data outputs
have been programmed to withstand shorts to +12v to pre-
vent control panel damage
• Supports the PC5208 low current output module
• Supports zone doubling expanding the control panel from
6 to 12 zones
• AUX Power Supply Trouble
• Loss of internal clock
• Bell output trouble
• Telephone line trouble
• Low battery condition (panel)
• Quick Exit
• Cross Zone Burglary Alarm
• Rotating Keypress Buffer
• One Restart of Exit Delay